1. Applications
This electronic temperature controller is designed for
controlling the room temperature in conjunction with:
• heating systems e.g. hot-water heaters, convector hea-
ters or floor heating
• electric convector heaters, ceiling and storage heating
• night storage heaters
• circulation pumps
Features
• Nighttime set-back, input for external clock
Indicator lamps for "controller calls for heat" and for
set-back operation
• 2-poel mains switch
• Mounting in 55 mm appliance socket
2. Description of functions
2.1 Functions
The room temperature is measured by the integrated
sensor and is set via the outer dial.
The scale of *…6 corresponds to 5…30°C.
Lamps
Red: Controller calls for heat
Green: Set-back mode is activated
2.2 Functions of the set-back input TA
èè
The TA input is used to set the thermostat into the ener-
gy saving mode (by using an external timer).
In this mode, the room temperature will be reduced by
3° or 5° (depending on jumper J2).
2.3 Selecting the set-back temperature
By means of the J2 jumper it is possible to select 3° or
5°.
J2 closed* set-back by 5°C
J2 open set-back by 3°C
* = factory pre-set
The temperature set externally via the dial is reduced by
this value.
2.4 Remote sensor
For measuring the room temperature a remote sensor
can be used instead of the internal one.
If the remote sensor is connected, the internal one auto-
matically will be disabled.
Note: In order to change from remote sensor to inter-
nal sensor, master reset has to be activated (see 2.6).
The remote sensor is not part of delivery.
Caution-1!
The device may only be opened and installed ac-
cording to the circuit diagram on the device or these
instructions by a qualified electrician. The existing
safety regulations must be observed.
In order to comply with safety class II, the necessary
installation steps must be taken.
This independently mountable electronic device is
designed for controlling the temperature in dry and
enclosed rooms only under normal conditions.
The device confirms to EN 60730, it works according
operating principle 1C
2.5 Function of the lamps
Function Lamp green Lamp red
Heating is on on
Set-back mode on
external sensor failure blink blink
2.6 Master Reset
In case of unexpected behaviour of the controller
Master Reset should be carried out by performing the
following steps:
Note the state of Jumper 2
Switch off power supply
Change state of J2
Switch on power
Switch off power
Set the original state of J2
Switch on power.
Now the internal sensor is active.
3. Mounting / Commissioning
The controller should be mounted at a point in the
room which:
• can be easily accessed
• is free of curtains, cabinets, shelves, etc.
• allows free air circulation
• is not exposed to direct sunlight
• is not draughty (when doors or windows are opened)
• is not directly influenced by the source of heat/cold
• is not located on an outer wall
• is approx. 1.5 m above the floor.
Electrical connection
Perform the steps described below:
• Pull off the temperature dial
• Release the fixing screw
• Remove the upper part of the casing
• Connect acc. to circuit diagram (see bottom of casing)
Remote sensor
Do not install the sensor close to mains cables. In other
cases a shilded cable has to be used.
The sensor can be extended to max. 50 m by means of
a cable suitable for mains voltage.
Caution! Sensor leads carry mains voltage (230 V).
4. Technical data
Order designation RTE 5050 SN
Temperature setting range:*…6 (5…30ºC)
Indicator lamp red Controller calls for heat
green Set-back temperature
Power switch 2-pole
Supply voltage 230V AC (195…253V)
50Hz
Output Relay make contact
Switching current: 100mA…16A cosϕ = 1;
100mA… 2A cosϕ = 0.6
Control algorithm Proportional controller
(similar to continuous
through PWM)
Switching temperature
differential ~0,5°C
Temperature sensor: internal
Temperature set-back 3K or 5K selectable
via external timer
Range limitation inside the dial
Degree of protection
of casing IP30
Safety class II (see Caution-1)
Software class A
Degree of polution 2
Calculation impulse voltage 2,5 kV
Temperature for the
Ball compression test 75°C
Voltage and Current for
the for purposes of
interfernce measurements 230V, 16A
Ambient temperature 0…40ºC
Storage temperature –25…70ºC
Weight 90 g
Caution! De-energize the electric circuit first
Sensor characteristics
10°C 66.8 kΩ 30°C 26.3 kΩ
20°C 41.3 kΩ 40°C 17.0 kΩ
25°C 33 kΩ 50°C 11.3 kΩ
5. Circuit diagram
Caution:
Through-connector for earth (PE conductor)
Position of the jumpers
6. Dimensions
468 931 003 294-1
Instructions for use
and assembly
Electronic room temperature controller
with set-back input
RTE 5050 SN
Errors possible-subject to alterations 280927/34615/2/0743
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG RTE 5050 SN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG RTE 5050 SN in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info