14 of 20 80000031353 BAL
5.1 External Connections
i
Establish the connections in accordance with the circuit
diagram provided. The mains connection line for the inde-
pendent power supply must be protected by the circuit
breaker specified in the technical data sheet. See the cir-
cuit diagram and the technical data sheet for possible
connection cross-sections.
System not installed correctly!
Risk to life due to electric shock.
Î Only trained and qualified skilled personnel who are
authorised to install medium-voltage systems may con-
nect such equipment.
Î Wear personal protective equipment.
Power terminals
-X41:1L+, 1L-
to
-X41:8L+, 8L-
DC connection Maximum 185 mm²
-X3:U, V, W Mains connection Maximum 3x150 mm²/phase
PE Earth connection Maximum 2x120 mm²
X6:1, 2 Compain master Maximum 4x95 mm²/pole
X6:3, 4 Compain slave Maximum 4x95 mm²/pole
Control/Monitoring terminals
-E1:1, PE, 2 Power supply 230 VAC
-X13:U, N, PE Auxiliary power supply 230 VAC
-X26:1, 2, 3, 4 Input Q26 external
-X33:1, 2 Signals (NC contact of S1, system stop)
-A12-X3, X4, X5 Remote signalling
-A13-X3, X4 Remote signalling
-A20-X3:1, 2, 3 Compain mode (optional)
Designated cable:
See cable diagram
DANGER
102


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Protect PV 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Protect PV 500 in the language / languages: English as an attachment in your email.

The manual is 1,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Protect PV 500

AEG Protect PV 500 User Manual - German - 136 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info