Protect PV.500 Maintenance and Servicing
12 of 14 80000031355 BAL
4.6.1 Removing and Installing the Fans
Risk of injury due to rotating fans!
The fans of the INV control cabinet are freely accessible.
Î Never reach into rotating fans.
Î When setting up any system, ensure that the fans can-
not be touched.
When fans are replaced, the starting capacitors must be replaced
too.
Removing the fan:
i
The fans switch on and off depending on the temperature.
Even after the system has been switched off the fans may
continue to run for a short time, until the unit temperature
drops. Do not remove connectors under load, i.e. when
the fans are running.
The power supply to the motors must be isolated before
any work is carried out on the fans!
Î Disconnect the corresponding connectors on the "fan monitor-
ing" assemblies.
INV control cabinet M1/X201 (DC/AC cabinet)
M2/A91.1 X1
M3/A91.1 X2
The fans in the INV control cabinet are located in the power sec-
tion's air duct and on the roof of the cabinet.
Stack fan M1 is located in the air duct of the INV power section at
the bottom of the cabinet.
Fans are replaced as described below:
Î Unscrew the cover from the air duct.
Î Disconnect the temperature sensor.
Î Unscrew the 6 fixing bolts on the fan holder and remove the
2 nuts; the fan is then resting on threaded bolts.
Î Pull the fan assembly out of the air duct towards you and set
it down.
Î Detach the fan connections and disconnect the cables.
Installing the fan:
Î Install the fan by repeating these steps in reverse order.
Î Switch on the system.
Î Check that the fan is functioning correctly.
CAUTION
86


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Protect PV 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Protect PV 500 in the language / languages: English as an attachment in your email.

The manual is 1,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Protect PV 500

AEG Protect PV 500 User Manual - German - 136 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info