Protect PV.250 Betriebsanleitung
Seite 27 von 52 80000027023 BAL, de
6.1.2 Technische Daten
Hardeware Daten MultiCom CCC (Baugruppe A29.1)
Stecker : Port1 RS232 für Konfiguration
und COM-Server-Anschluss
X2: D-Sub 9 pin (Buchse; isoliert)
Port2 RS232/RS485 für Modbus
X5: D-Sub 9 pin (Buchse; isoliert)
RS-485 Verbindung: Twisted pair mit Data+, Data-,
geschirmt, Schirm einseitig aufgelegt
Entfernung: 1.200m max bei 9600 baud.
Busteilnehmer: max. 32
Datenleitung: geschirmte 1:1 Datenleitung
(2 x 0,22; Twisted pair)
z.B."UNITRONIC-BUS LD" von Fa.
Lapp
Port3 CAN-Bus für Ferntableau
X4: 3polig Combicon-Stecker
Kommunikations Daten Port1 (X2)
Protokoll: CBSER
Übertragungsrate: 1200 - 57600 baud (einstellbar)
Übertragungsparameter: 9600 baud, 8, E, 1 (Default)
Konfigurationsmodus: 9600 baud, 8, N, 1
Kommunikations Daten Port2 (X5)
Protokoll: Modbus
Übertragungsmodus: Halb Duplex
Übertragungs Code: RTU
Übertragungsrate: 1200 - 57600 baud (einstellbar)
19200 baud (Default)
Start Bits: 1
Daten Bits: 8
Parität: keine, gerade, ungerade (einstellbar)
Stop Bits: 2 wenn keine Parität, 1 wenn Parität
Funktions Code: 03 (Register lesen)
06 (Register schreiben)
16 (mehrere Register schreiben)
Min. Antwortzeit des Slaves: 0-99 ms einstellbar (0ms Default)
Modbus-Slaveadresse: 01-99 (einstellbar) (01 Default)
Kommunikations Daten Port3 (X4)
Protokoll: CAN-Bus Proprietär
Übertragungsrate: 50 kbaud
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Protect PV 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Protect PV 250 in the language / languages: German as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Protect PV 250

AEG Protect PV 250 User Manual - English - 51 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info