473801
7
Zoom out
Zoom in
Previous page
1/24
Next page
2.1.3. Status
Menu Structure - Status
Display Functions Description
[-] Ambient Conditions Only applicable if sensors are connected
Irradiance: 1400W/m
2
Irradiance. “NC” if not connected
PV module temp: 100
o
C
PV module temperature. “NC” if not connected
Ambient temp: 20
o
C
Ambient temperature. “NC” if not connected
Irr. sensor temp: 20
o
C
Irradiation sensor temperature. “NC” if not connected
[-] Photovoltaic
[-] Present values
[-] PV input 1
Voltage: 1000V Voltage detected at PV input 1
Current: 15.0 A Current detected at PV input 1
Power 10000 W Power detected at PV input 1
[+] PV input 2
[+] PV input 3 Not visible if inverter type is 10 kW
[-] Isolation Resistance
Resistance: 45 MΩ PV isolation at start up
[-] PV Input Energy
Total: 369000kWh Daily production of all PV inputs
PV1: 123000 kWh Daily production of PV input 1
PV2: 123000 kWh Daily production of PV input 2
PV3: 123000 kWh Daily production of PV input 3
[-] PV Configuration
PV input 1: Individual
Configuration of PV input 1. The configuration is only shown when the in-
verter is in Connecting or On grid mode.
PV input 2: Individual
PV input 3: Individual
[-] AC-grid
[-] Present Values
[-] Phase 1
Voltage: 250 V Voltage on phase 1
Current: 11.5 A Current on phase 1
Frequency: 50 Hz Frequency on phase 1
Power: 4997 W Power on phase 1
[+] Phase 2
[+] Phase 3
[-] Residual Current Monitor
Current: 350 mA Residual current in mA
[-] Grid management Only visible if the inverter is set up for feed-in to medium or high voltage
grid (e.g. _MV country is the selected country)
[-] Power level adjustment
[-] Present limit: 100 %
Maximum allowed power output in % of nominal power output. “Off”
means that the power level functionality has been disabled in the inverter.
[-] Reactive power Only displayed if the current country setting is an MV country or custom,
and in Protect PV versions.
Setpoint type: Off
The setpoint type for Reactive Power. Off means that no internal setpoints
are used, but the inverter will accept an external setpoint.
Value: -
The current value of the setpoint for reactive power, the unit depends on
the selected setpoint type.
Table 2.3: Status
2. Display
6 8000038784_00_BAL_en / L00410565-01_02
2
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG PROTECT PV 12.5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG PROTECT PV 12.5 in the language / languages: English as an attachment in your email.

The manual is 0,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG PROTECT PV 12.5

AEG PROTECT PV 12.5 User Manual - German - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info