473796
26
Zoom out
Zoom in
Previous page
1/33
Next page
Parameter Specification
Temperature -25°C - +60°C (>45°C derating)
Environmental class according to IEC IEC60721-3-3
3K6/3B3/3S3/3M2
Air quality ISA S71.04-1985
Level G2 (at 75%RH)
Coastal, heavy industrial and farmer areas Must be measured and classified acc. to ISA S71.04-1985
Vibration 1G
Ingress protection class 54
Max. operating altitude 3000m above sea level.
PELV protection is effective up to 2000m above sea level only.
Installation Avoid constant stream of water.
Avoid direct sunlight.
Ensure adequate air flow.
Mount on non-flammable surface.
Mount upright on vertical surface.
Prevent dust and ammonia gases.
Table 5.3: Conditions for Installation
Parameter Condition Specification
Wall Plate Hole diameter 30 x 9 mm
Alignment Perpendicular ± 5° all angles
Table 5.4: Wall Plate Specifications
5.1.1. Cable Requirements
Cable Condition Specification
AC 5 wire cable Copper
Outer diameter 18-25 mm
Insulation strip All 5 wires 16 mm
Max. recommended cable length
Protect PV 10
2.5 mm
2
21 m
4 mm
2
34 m
6 mm
2
52 m
10 mm
2
87 m
Max. recommended cable length
Protect PV 12.5
4 mm
2
28 m
6 mm
2
41 m
10 mm
2
69 m
Max. recommended cable length
Protect PV 15
6 mm
2
34 m
10 mm
2
59 m
PE Cable diameter at least as phase cables
DC Max. 1000 V, 12 A
Cable length
4 mm
2
- 4.8 Ω /km
< 200 m*
Cable length
6 mm
2
- 3.4 Ω /km
>200-300 m*
Mating connector Multi-contact PV-ADSP4./PV-ADBP4.
* The distance between inverter and PV array and back, plus the summarised length of the cables used for
PV array installation.
Table 5.5: Cable Requirements
Note:
Avoid power loss in cables of more than 1 % of nominal inverter rating.
Note:
In France, observe the UTE C 15-712-1 and NF C 15-100 requirements.
5. Technical Data
8000038781_00_BAL_en / L00410564-01_02 25
5
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Protect PV - Solar Inverters at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Protect PV - Solar Inverters in the language / languages: English as an attachment in your email.

The manual is 4,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Protect PV - Solar Inverters

AEG Protect PV - Solar Inverters User Manual - German - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info