8. TROUBLE SHOOTING GUIDE
You can solve many common Wine cellar
problems easily, saving you the cost of a
possible service call. Try the suggestions.
Problem Possible cause Solution
Wine cellar
does not
operate.
• Not plugged in.
• The appliance is turned o.
• The circuit breaker tripped.
• Demo Mode is active.
• Please connect the appliance.
• Please turn ON the appliance.
• Turn on the circuit breaker.
• Deactivate the Demo mode (press +/- for 3sec.).
Wine cellar
is not cool
enough.
• Check the temperature control setting.
• The door is not completely closed.
• The door gasket does not seal properly.
• Verify the set temperature.
• Verify the closure of the door.
• Clean the door gasket with a humid sponge
using neutral detergent and water.
The
compressor
operates
continuously.
• The room temperature is hotter than
normal.
• The door is opened too often.
• The door is not completely closed.
• The door gasket does not seal properly.
• Verify the room temperature.
• Do not keep the door open longer than necessary.
• Verify that the door is completely closed.
• Verify the gasket condition and in case clean it with
a humid sponge using neutral detergent and water.
The light
does not work.
• Not plugged in.
• The circuit breaker tripped.
• The LED has burned out.
• The light button is not operating.
• Please connnect the appliance.
• Turn on the circuit breaker.
• Contact the service.
• Contact the service.
Too much
vibration.
• Check that the wine cellar is levelled. • Level the appliance.
Too much
noise.
• The rattling noise may co me from the ow
of the refrigerant, which is normal.
Contraction and expansion of the inside walls
may cause popping and crackling noises.
• The wine cellar is not level.
• Fan is dirty.
• Level the appliance.
• Clean the fan from powder.
• If the noises become louder contact the
service.
The door does
not close
properly.
• The wine cellar is not level.
• The door was xed not properly.
• The gasket is dirty.
• Level the appliance.
• Verify the closure of the door.
• Clean the door gasket with a humid sponge
using neutral detergent and water.
Acoustic alarm
• The door is not closed (the alarm lasts
30 min).
• Close the door.
E3 is displayed
• The door was left open for more than
30 min.
• Door reed switch is broken.
• Close the door.
• Contact the service.
E1 is displayed
and an acoustic
alarm will sound
every 5 minutes.
• The temperature inside the wine cellar
is outside the range of -20°C +60°C
• The temperature sensor is out of order
or disconnected.
• Verify absence of heating from nearest
appliances.
• Contact the service.
E2 is displayed
• Warm coming from nearest appliances.
Ambient temperature is out of the
product climate class Range.
• Compressor or fan are out of order.
• Verify absence of heating from nearest appliances.
• Verify if the product is installed in a place with
ambient temperature within declared product
climate class.
• Contact the service.
www.aeg.com
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG KWK884520M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG KWK884520M in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 3,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG KWK884520M

AEG KWK884520M User Manual - Dutch, Portuguese, Spanish - 38 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info