5.
Replace the rating plate (it is near
the gas supply pipe) with the one for
the new type of gas supply. You can
find this plate in the package sup-
plied with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure ad-
juster on the gas supply pipe.
8.3 Adjustment of minimum
level
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the
by-pass screw position.
A
A)
The by-pass screw
If you change from natural gas G20 20
mbar to liquid gas, fully tighten the
by-pass screw in.
If you change from liquid gas to natu-
ral gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn (1/2
of a turn for Triple Crown burner).
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.4 Electrical connection
Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.
This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug which can hold the load that
the rating plate rates. Make sure that
you install the plug in a correct socket.
Always use a correctly installed shock-
proof socket.
Make sure that there is an access to
the mains plug after the installation.
Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
There is a risk of fire when the appli-
ance is in connection with an exten-
sion cable, an adapter or a multiple
connection. Make sure that the
ground connection agrees with the
standards and regulations.
Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect the blue
neutral cable to the terminal with a letter
"N" on it. Connect the brown (or black)
phase cable to the terminal which has a
letter "L". Keep the phase cable connec-
ted at all times.
8.5 Replacement of the
connection cable
To replace the connection cable use on-
ly H05V2V2-F T90 or equivalent type.
Make sure that the cable section is appli-
cable to the voltage and the working
temperature. The yellow/green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
ENGLISH 13
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG Electrolux HG995440XB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG Electrolux HG995440XB in the language / languages: Italian as an attachment in your email.

The manual is 3,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AEG Electrolux HG995440XB

AEG Electrolux HG995440XB User Manual - Dutch - 20 pages

AEG Electrolux HG995440XB Additional guide - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info