648349
38
Zoom out
Zoom in
Previous page
1/100
Next page
38
Installation – for qualied contractors
13.3 Details on energy consumption
Product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP).
DDLE ÖKO TD 18 DDLE ÖKO TD 18/21/24 DDLE ÖKO TD 27
222396 222398 222399
Manufacturer AEG Haustechnik AEG Haustechnik AEG Haustechnik
Load profile S S S
Energy efficiency class A A A
Annual power consumption kWh 477 477 481
Energy conversion efficiency % 39 39 39
Default temperature setting °C 60 60 60
Sound power level dB(A) 15 15 15
Special information on measuring efficiency None Data at Pmax. Measured with flow restric-
tion on 9 Ltr/min
13.4 Wireless remote control
Model FBM Comfort
Dimensions (H/W/D)
excl. wall retainer
50/50/17 mm
Weight excluding wall retainer 30 g
Radio frequency 868.3 MHz
Range inside building
incl. one separating ceiling
25 m approx.
Temperature setting range 30 °C - 60 °C
Protection level to EN 60529 Shower = IP X5
Bath = IP X7
Battery type CR 2032
13.5 Appliance
DDLE ÖKO TD 18 DDLE ÖKO TD 18/21/24 DDLE ÖKO TD 27
222396 222398 222399
Electrical details
Rated voltage V 380 400 415 380 400 415 380 400
Rated output kW 16.2 18 19.4 16.2/19/21.7 18/21/24 19.4/22.6/25.8 24 27
Rated current A 24.7 26 27 27.6/29.5/33.3 29/31/35 30.1/32.2/36.3 37.1 39
Fuse A 25 25 32 32/32/35 32/32/35 32/32/40 40 40
Phases 3/PE 3/PE 3/PE
Frequency Hz 50/60 50/60 50/- 50/60 50/60 50/- 50/60 50/60
Max. mains impedance at 50Hz Ω 0.379 0.360 0.347 0.284 0.270 0.260 0.254 0.241
Specific resistance ρ
15
≥ (at ϑcold ≤25 °C) Ω cm 900 900 1000 900 900 1000 900 900
Specific conductivity σ
15
≤ (at ϑcold ≤25 °C) μS/cm 1111 1111 1000 1111 1111 1000 1111 1111
Specific resistance ρ
15
≥ (at ϑcold ≤45 °C) Ω cm 1200 1200 1300 1200 1200 1300 1200 1200
Specific conductivity σ
15
≤ (at ϑcold ≤45 °C) μS/cm 830 830 770 830 830 770 830 830
Connections
Water connection G 1/2 A G 1/2 A G 1/2 A
Application limits
Max. permissible pressure MPa 1 1 1
Max. inlet temperature for reheating °C 45 45 45
Values
Max. permissible inlet temperature °C 65 65 65
ON l/min >2.5 >2.5 >2.5
Flow rate for pressure drop l/min 5.2 5.2/6.0/6.9 7.7
Pressure drop at flow rate MPa 0.08 0.08/0.1/0.13 0.16
DHW delivery l/min 9.9 9.9/11.6/13.2 14.9
Δϑ at DHW delivery K 26 26 26
Hydraulic data
Rated capacity l 0.4 0.4 0.4
Versions
Connected load options - X -
Temperature adjustment °C 30-60 30-60 30-60
Insulation block Plastic Plastic Plastic
Heating system heat generator Bare wire Bare wire Bare wire
Cap and back panel Plastic Plastic Plastic
Colour white white white
IP-Rating IP25 IP25 IP25
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG DDLE OKO TD24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG DDLE OKO TD24 in the language / languages: English, German as an attachment in your email.

The manual is 25,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info