OVERALL DIMENSIONS Width: 580 mm.
Depth: 500 mm.
CUT OUT DIMENSIONS Width: 550 mm.
Depth: 470 mm.
SUPPLY CONNECTIONS Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge fuse.
IGNITION HT SPARK Spark Generator
Ispra Control's BF 80066 - 220-240V 0.6 VA T120
Spark Gap : Fixed
HEAT INPUT
Rear Left Burner 2.0 kW (6824 BTU/HR)
(semi rapid)
Front Left Burner 3.0 kW Natural Gas (10236 BTU/HR)
(rapid) 2.8 kW L.P.G. (9554 BTU/HR)
Rear Right Burner 2.0 kW (6824 BTU/HR)
(semi rapid)
Front Right Burner 1.0 kW (3412 BTU/HR)
(auxiliary)
APPLIANCE CLASS 3
APPLIANCE CATEGORY II2H3+
GAS SUPPLY Natural gas G20 / 20mbar
Instructions for the Installer
Engineer technical data
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG 11602 G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG 11602 G in the language / languages: Dutch as an attachment in your email.

The manual is 0,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info