3.2.1 How to operate Aduro-tronic
When lighting
When lighting a fire in the stove for the first time, the maximum
amount of primary air will be needed to light the fire. For that reason,
the primary damper can be kept “forcibly open”. This is done by
pulling the primary damper forward as far as possible and then fixing
it with the Aduro Key (see illustration). When the stove is warm and a
layer of embers has been created on the bottom of the combustion
chamber, the Aduro-tronic can be set to the automatic position, i.e.
the Aduro Key can be removed. Alternatively, you can leave the door
ajar the first minutes during lighting the fire (without the key).
When stoking
Each time fresh wood is put in the stove, a precise amount of primary
air will be allowed in for the first few minutes. What’s more important
is that the primary air is not allowed in for too long. This is to ensure
optimum combustion. The Aduro-tronic control will ensure intake of primary air at the right tempo. The
automatic is activated by pulling the primary damper out each time fresh wood is put in the stove. The
automatic closes then the primary air gradually.
Regulation of the Aduro-tronic control
The control is pre-set to close the primary air intake within 6 minutes. This setting has been used during
testing at the Danish Technological Institute using a standard chimney and ‘standard’ sized logs (approx. 30
cm long, 10x10 cm thick) with maximum moisture content of 18%. In practice, such circumstances can differ,
which is why the Aduro-tronic control can be adjusted to your circumstances. If you want a slower intake of
primary air (e.g. for a slower flue draft, larger sized wood or for longer intervals between stoking), adjust the
screw on the front of the control level using a small allen key to slow closure rate. If the screw is turned to the
right, closing time is increased and if turned to the left, closing time is reduced.
3.3 How should I use my wood burning stove?
The wood burning stove is intended for intermittent combustion. This means that each stoking should burn
down to embers before new logs are added.
To obtain the best possible combustion, you should regulate the effect/heat output with the fuel. Burning
small logs provides more powerful combustion than burning large logs as the surface area is greater and
more gas is released. The amount of wood in the combustion chamber is another factor that affects
combustion. The optimum combustion is achieved by placing two logs in the stove. If you want an enhanced
effect, you can add more logs. The ideal heat output is reached by burning approx. 1.5 kg per hour.
Use of dry wood of the right size is important to achieve optimum
combustion.
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aduro 9 Air at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aduro 9 Air in the language / languages: Italian, Spanish as an attachment in your email.

The manual is 3,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aduro 9 Air

Aduro 9 Air User Manual - English, German - 55 pages

Aduro 9 Air User Manual - Dutch - 13 pages

Aduro 9 Air User Manual - Danish, French, Swedish - 55 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info