2.3 Pipe connection
Aduro 9.4 leaves the factory with the flue outlet mounted on the top. If you require the flue outlet on the back,
“brake” the two cover plates on top of the back of the stove. Exchange the exhaust connector (from the top
outlet) with the cover plate from the rear outlet. Mount the cover plate from the rear outlet to the top outlet.
The top outlet is finished with the plate that lies in the ashpan. A flue pipe with an internal diameter of 150
mm should be used for Aduro stoves.
Please ensure that all local rules and regulations are complied with, including CE marking of the exhaust
connector. Additionally, distance requirements to flammable material for the exhaust connector must be
respected.
2.4 Connection to a brick chimney
If the stove is being connected to a brick chimney, the rear outlet or a curved flue pipe via the top outlet
should be used. After measuring, a hole is made in the chimney in which the pipe sleeve is placed and stove
mortar is used to seal it in place. The stove is placed in position and the flue pipe is put in place. A thin
gasket is placed between the flue pipe and the pipe sleeve to seal the joints. The flue pipe should protrude
into the pipe sleeve, but must not block the opening in the chimney (see the illustration below):
The stove can be connected to a chimney to which other heat sources are connected.
3. Lighting the stove
Important safety information
• The wood burning stove will become warm during use and therefore it should be treated with all
necessary caution.
• Never keep easily combustible fluids such as petrol in the vicinity of the wood burning stove.
• Never use easily combustible fluids to light the fire in the wood burning stove.
• Never empty the ashpan when the wood burning stove is warm. Embers may still be found in the
ashpan for up to 24 hours after the fire has gone out. Please wait to empty the ashpan until you
are sure that there are no embers in the ash.
• The door should be kept closed while the wood burning stove is in use. While lighting the fire, the
door can stand ajar for the first few minutes.
• In the event of a chimney fire: Close all the dampers on the wood burning stove and call the fire-
fighting service.