level should not exceed 18 %, which roughly corresponds to storing the wood under cover outdoors for one
year. The moisture level of the wood can be measured using a moisture meter or by applying dishwashing
liquid to one end of the log and blowing air in the other end. If the wood is dry enough, soap bubbles will
appear. The wood should be chopped into logs with a diameter of approx. 10 cm and a log length of max. 39
cm. Firing with wet fuel will reduce the energy efficiency and increase the particle emission.
Burning varnished wood, impregnated wood, chipboard, paper, and other waste is strictly forbidden. Burning
these materials will damage the environment, the wood burning stove, and your own health. Fossil fuels
must not be used.
4. The chimney
The optimum combustion is achieved at a constant chimney draft of 10-14 Pascal (Pa) measured in the flue
pipe above the stove (when having a smoke exhauster). However, with natural draft (chimney without smoke
exhauster) the draft in the chimney will be between 18-25 Pa when conditions are optimum. There are many
factors that affect the chimney draft, including the outside temperature, wind strength, and surrounding
buildings. There are no requirements with respect to specific chimney heights, but a chimney must be tall
enough to provide a good draft. If the recommended chimney draft is not achieved, there may be problems
with smoke out of the door by firing.
Data for chimney calculation
Wood
Flue temperature at [20°C]
245
Chimney draft at testing power [mbar]/[Pa]
0.12 / 12
Flue gas mass flow [g/s]
5.7
4.1 Inadequate draft in the chimney
If the chimney is too short, leaks, or is inadequately insulated, there may be problems with the chimney draft
(let the chimney sweep assess this). The draft should be sufficient during the ignition phase when the
stove/chimney is cold to provide a clean combustion and prevent smoke leakage. Therefore, we recommend
a chimney draft around 5 Pa in the ignition phase.
Once the ignition is a success and the smoke temperature is rising, it is important that the chimney draft
reaches a stable area around 18-25 Pa in operation (1 hour after ignition) when the chimney/stove is hot.
The draft in the area of 18-25 Pa when the stove is hot is essential in order to achieve an optimum and clean
combustion. Therefore, we recommend that you measure your chimney draft when the chimney is cold and
when it is hot after 1 hour in operation.
In practice, the chimney draft will differ especially in cold condition. Therefore, the best indication of the
chimney draft is to measure the draft when it is hot. If the chimney sweep judges the draft to be sufficient, but
you still have problems lighting a fire, try extending the fire lighting phase by using more thin pieces of
kindling and 1-2 firelighters, so that the chimney gets thoroughly warm. The chimney will not draw at
optimum effect until it is warm. When a layer of embers has been formed, add 2-3 dry logs.
If it is impossible to establish a sufficiently natural chimney draft, the chimney can be fitted with a smoke
exhauster, e.g. Aduro DraftOptimizer.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aduro 9-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aduro 9-1 in the language / languages: Italian, Spanish as an attachment in your email.

The manual is 1,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aduro 9-1

Aduro 9-1 User Manual - English, German - 43 pages

Aduro 9-1 User Manual - Dutch - 10 pages

Aduro 9-1 User Manual - Danish, French, Swedish - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info