Color Presets Lists color scheme presets that come with the program as well as those you’ve created yourself. To
choose one, select it from the pop-up menu.
Save As Saves the currently selected color scheme as a preset.
Delete Deletes the currently selected color scheme preset.
Example Displays the currently selected color scheme preset or customized color scheme.
Change Color Opens the Color Picker, in which you can select a new color for the element selected under Waveform.
(The current color is shown in the color swatch to the left of the Change Color button.)
Selection Lets you adjust the appearance of a selected range. Preview your changes in the Example area.
Invert Completely reverses the color of selected ranges relative to unselected audio. Deselect this option if you
want to set transparency for selected ranges instead of reversing the colors.
Transparency Drag the slider or enter a value to adjust the transparent value (in percentage) of a selection; 0 is no
transparency, and 100 is maximum transparency. (This option is not available when Invert is selected.)
UI Brightness Drag the slider, click the arrows at either end of the brightness scale, or type in a percentage to change
the overall brightness of the work area.
Tint Colors all panels and dialog boxes with a tint you specify.
Reset UI Returns UI Brightness and Tint to the default settings.
Display preferences
In the Preferences dialog box, click the Display tab to adjust the Spectral and Waveform Display modes:
Windowing Function Determines which method Adobe Audition uses to segment the spectral data before
displaying it. The segments (windows) are listed in order from the narrowest frequency band/most noise to the
widest frequency band/least noise. Blackmann or Blackmann-Harris are usually good choices.
Resolution Specifies the number of vertical bands used in drawing frequencies. The larger this number, the longer
it takes for Adobe Audition to render the spectral display. Performance varies according to the speed of your
computer.
Window Width Specifies the window width (FFT frame size) used to plot spectral data, where 100% is a full frame.
The default setting is 75%. If you want to increase time resolution and determine exactly where frequencies start,
decrease the window width (50% to 75% works best). This makes the display more accurate along the timeline (left
and right), but less accurate along the frequency scale (up and down).
Decibel Range Adjusts the visible amplitude range for Spectral Frequency Display.
Initial Viewing Range Determines the default length of audio that the Top/Tail Views option displays.
Link Top/Tail Zoom Levels Automatically matches zoom levels in each view.
Show Marker And Range Lines Displays marker and range lines in the waveform display. Marker and range entries
listed in the Marker List appear in the waveform as vertical dotted lines overlaying the audio, connecting the arrows
from the top to the bottom of the display.
Show Grid Lines Displays grid lines in the waveform display. The grid lines mark off time on the horizontal x-axis
and amplitude on the vertical y-axis.
Show Center Lines Displays center lines in the waveform display. The center lines represent zero amplitude of the
waveforms right and left channels.
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Adobe Handleiding Adobe Audition 3.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Adobe Handleiding Adobe Audition 3.0 in the language / languages: English as an attachment in your email.

The manual is 17,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info