802402
11
Zoom out
Zoom in
Previous page
1/168
Next page
11
setting temperature, so the digital display (T) will show “--”. After continuous heating for 12 hours, the fan will blow cool air fpr 30
seconds, then the device stops blowing and will enter into standby mode.
2.5. SETTING THE WEEKLY PROGRAM – available by the remote control (4) only. FigureS: XVII – XXI.
NOTE: Before turn on weekly program: it must set days of work and work time period (P1-P6) , otherwise the weekly default state is “00”,
the product does not work.
After complete setting of current TIME / DAY (points 2.3.1 and 2.3.2) , below are listed steps to set weekly program:
2.5.1 Press button (A) on remote control, the product enter into working status.
2.5.2 Press the weekly program button (K) , the display (5) shows icon K1, the device enters into weekly program setting. Look at figure
XVII.
2.5.3 Press day button (J) , the digital display (T) shows “d1” , then press repeatedly the day button (J) to set desired working day
(Monday-Sunday: d1~d7). Look at figure XVIII to see the example setting for Monday.
2.5.4. Press the edit button (M), the display (5) shows “P1”- period one - as default, press the edit button (M) to set time period (P1-P6).
Note: It can be set maximum 6 time periods for each working day, while setting any time and adjust temperature.
Follow step 2.5.5 – 2.5.7 below to set: turn-on time / turn-off time / desired temperature for each time period (P1-P6). Setting P1 shown
at figure XIX.
2.5.5. Press the time on button (L), the digital display (T) shows "00" by default. Press the timer on button (L) once in increments of one
hour as many times as necessary to set the desired on time (00-24 hours). Example: set the on time to 7:00 am - see picture XX.
2.5.6. Press time-off button (N) to set up the stop of time period, the digital display (T) shows the previous turn-on time by default. Press
time-off button (N), each one time pressing increases one hour to set the turn-off time in range: 00-24 hours. Example: setting the turn-
off time 13:00 p.m. – look at figure XXI.
The desired time switch off hour cannot be earlier than desired time-on hour.
When the desired time-on (start of period) is the same as the desired time – off (stop of period), the device enters into standby mode.
2.5.7. Press the plus (F) or the minus (E) buttons repeatedly to setting the desired temperature in range from 10 to 49 degree of Celsius.
2.5.8. Repeat steps 2.5.3 – 2.5.7 described above to set the weekly program for all device working day you want.
2.5.9. Then press the confirmation button (G) to confirm the settings.
2.5.10 To cancel the weekly program function, press the button (K) again , the icon (K1) will go off. The weekly program is off.
Note: After the above setting are completed and weekly program is working, the icon K1 is illuminated on the display (5), then:
- press the day button (J) to check with set working day (d1-d7),
- press the edit button (M) to check with time period (P1-P6),
- press the time-on button (L) to check with the set turn-on time,
- press the time-off button (N) to check the set turn-off time.
2.6. OPEN WINDOW DETECTION MODE SETTING - available by the remote control (4) only.
2.6.1. Press the button (A) on your remote control (4)the device enters into working status. Let the device heating for a moment until
operate stable.
2.6.2. Press the button (O) by remote control, the icon (O1) will be on display (5). The temperature display “23”by default. Press the plus
(F) or the minus (E) buttons repeatedly to set target temperature. During open-window detection mode, once the ambient temperature
drops 5-10 degree of Celsius within 10 minutes, then the device will stop working and enter into standby mode. Then press the button
(A) to turn on the device.
Press the button (O) again to turn off the open-window detection mode, the icon (O1) will off at display (5) and the device will resume to
previous working mode.
Below is an example to set 23 degree of Celsius during open-window detection mode. Look at figure XI.
2.6.3 When turn on at the same time for both open-window detection and weekly program, during the OFF period of weekly program, the
device does not operate. During the working status of weekly program, the temperature is subject to the setting temperature of open-
window detection mode. Look at figure XII.
2.7 REMOTE CONTROL
Follow the instructions of use and the recycle rules given on the battery packaging. The procedure of battery replacement is described
below – look at figure XXII.
1. Open the battery compartment by sliding the cover down.
2. Insert the battery into the compartment. The remote control requires 1 CR2025 3V lithium battery (not included).
3. Close the battery compartment.
CLEARING AND MAINTENANCE
1. Before cleaning switch off the main power switch (1), plug out the device and let the device to cool down.
2. A common cause of overheating is deposits of dust or fluff in the appliance. Ensure these deposits are removed regularly by
unplugging the device and vacuum-cleaning air inlets (7) and air outlets (6), where available.
3. Do not use abrasive cleaning products on this device. Clean with a damp cloth (not wet) rinsed in hot soapy water only.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Adler CR 7747 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Adler CR 7747 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 3.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info