Troubleshooting
1) Trouble: Do not work.
The protective device will work in the following cases:
2. If the plug has been removed, after restarting the device will return to the original mode, TIMER ON and TIMER OFF - must be set again.
If the device runs in cooling “K” or dry “L” mode with door or window opened for a long time when relative humidity is above 80%, dew may
drip down from the outlet.
1. Restarting the device immediately after stopping work or changing the selected mode while working, you must wait 3 minutes.
REMARK: there is condensing water recycling hidden within this unit. The condensing water is partly kept recycling between the condenser
and the water plate. When the water level rises to the upper level, the float switch and water full indicator (E4) lights on to remind draining
water. Please cut off the power supply, move the appliance to a suitable place, remove the drain plug, drain water completely. After the
drain, re-install the plug, or the appliance may leak and make your room wet. Drain pipe is added to kit, with inner diameter 9mm, outer
diameter 12mm, material: PVC.
2. The compressor will stop after running 8 minutes, then run again after 6 minutes.
1. The up centrifugal fan will run at low speed, and the speed can't be adjusted.
COOLING "K" mode:
- When the room temperature 24 , the unit will automatically select high fan speed mode "M..".
DEHUMIDIFYING "L" mode:
1. When the room temperature is higher than set temperature on control panel, the compressor starts to run.
2. When the room temperature is lower than set temperature on control panel, the compressor stop and upper fan operates at original set
speed.
Fan "M." mode.
1. The up centrifugal fan runs at set speed, and the compressor does not run. .
3. The device adopts constant temperature dehumidifying mode, and the adjustment of temperature is no effective.
The main control board has memory function, when the device is ready to run but in stop status, the main control board can memorize the
initialization of working mode. When you turn on the unit, it will work as the same enactment of working-mode as last time, no need to reset
the working mode again. (This condition is not available when the unit is under AUTOMATIC mode "J".)
2. The adjustment of temperature is no effective.
Notice:
Timer operation "N":
REMOTE CONTROLLER
To operate the device, aim the remote controller (4) at the signal receptor (3). The remote controller will operate the device at distance 5
meters when pointing at signal receptor of the device.
PROTECTIVE DEVICES
4. To prevent environmental pollution, take out the used batteries and dispose safety and appropriately.
The protective device may trip and stop the appliance in the cases listed below:
3. For long time no use, take out the batteries.
2. at cooling mode: room temperature is below 15°C (59°F)
2. Put the batteries inside the slot, must be corresponding to the signs of "+" and "-" on the remote control.
Sleeping mode "I" operation:
3. at dehumidifying mode: room temperature is below 15°C (59°F).
1. Slide the back cover to open and take off the isolating film on the batteries.
2. Press “N” button to set Automatic On time while the unit is ready.
1. Press “N” button to set Automatic Off time while the unit is running.
1. at cooling mode: indoor air temperature is over 43°C (109°F)
3. The time can be adjusted within a range of 1 hour to 24 hours by pressing the button "D"+or "E"-.
1. The sleeping mode operations when the unit is under cooling "K" mode.
2. Press the button "I" in cooling mode "K" , then the unit will work under sleeping mode and the up centrifugal fan will turn to low speed
automatically. The set temperature will increase by 1 after one hour, and increase 2 after two hours. After six hours the unit will stop
running.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Adler AD 7924 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Adler AD 7924 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 20.16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info