3. Turn on the device using the power switch (A) button on the control panel (Fig. C). default setting is middle fan speed. Press power
switch (A) again, product is in standby.
4. The fan speed button (E) on the control panel (9) allows you to change the speed of the fan. The following fan speeds can be selected
by pressing again: medium (H) -> slow (G) -> fast (H) -> medium (H) -> …
5. Cooling / Humidify button (B) lowers the temperature of the air by running the water pump. Additionally, you can put to upper water
tank (2) attached plastic containers (3). Plastic containers (3) should be filled up to max level by water and frozen in the freezer in
advance.
To blow the cool air, the device must be filled with water. When the device is operating, periodically check the water level to see whether
to add water. NEVER switch on the water pump when the bottom water tank (6) is not filled by water to minimum level at least.
a)Unplug the device, remove the screw of the back housing and then take mesh filter (11) and evaporation paper filter (13) out.
b)Wash the evaporation paper filter (13) in a mild detergent and warm water solution by soft brush, then rinse in clean water. Take care
not to pierce the evaporation paper filter (13).
-on fan speed set to low speed (G): the fan will blow 5 seconds at low speed and turn off for 5 seconds and next repeat this cycle;
-on fan speed set to fast speed (I): the fan will blow 30 minutes on fast speed natural mode then switch to middle speed natural mode
for 30 minutes, then switch to low speed natural mode.
-on fan speed set to low speed (G): the fan will run the same as low speed natural mode;
8. The mode choice button (C) allows for changing the fan mode. In addition to the normal fan air wind mode, you can select natural and
sleep modes.
-on fan speed set to middle speed (H): the fan will blow 5 seconds on each speed: middle , low, middle, stop, low, middle, low, stop and
next repeat this cycle;
c)Wash the mesh filer (11) with flowing clean water. Use a soft brush for cleaning.
1. Clean with soft, dry cloth. Do not use chemical solvents because they can cause permanent damage or deformation of the device.
3. After long time operation, mesh filter (11) and evaporation paper filter (13) will be clogged with the dust, which will greatly affect the
machine’s performance of cooling. If long time no changing water, there may be mold and mildew. We suggest to clean the mesh filter
(11) and evaporation paper filter (13) once every two weeks. The clean procedure is as below:
d) Dry both filters. The evaporation paper filter (13) must be installed flatly in order to avoid leakage. Screw bracket (15) with evaporation
paper filter (13) and mesh filter (11) to housing.
4. Drain the water before storage by removing the drain plug (12) at the bottom of the water tank after each use.
7. The TIMER button (F) allows for programming the amount of time during which the device will operate before turning itself off
automatically. Available time period selection is: 2-4-6-8-10-12 hours.
Normal fan mode (J) allows to set up fan speed between: medium (H) -> slow (G) -> fast (H) -> medium (H) -> … Each time the fan is
turned on again it will start operation in normal mode.
The natural mode (K) mimics the natural wind action by repeating the fan speed sequence:
-on fan speed set to fast speed (I): the fan will blow 5 seconds each speed: middle, low, fast, middle, fast, low, fast, stop and next repeat
this cycle.
-on fan speed set to middle speed (H): the fan will blow 30 minutes on middle speed natural mode, then switch to low speed natural
mode;
To start remote control (14) operation pull out the installing film. To replace the battery push the release tab and take battery out the
battery carriage. Replace by same type battery.
Sleep mode (L) was designed to use the effects of nature wind to easier fall asleep. It will gradually decrease the speed of fan in 30
minute increments:
CLEANING AND MAINTENANCE
Please ensure that the device and all of its parts are cleaned regularly to reduce the risk of limescale and bacteria forming. Unplug the
device before cleaning. Do not soak the control panel in water.
6. Pressing the horizontal air osculation button (D) to start the oscillation of slats that provide even distribution of cold air stream in range
70°. Horizontal louvers (4) do not move automatically, so if necessary, manually adjust them to point up or down.
2. If the device is not used for three or more months, take the batteries out of the remote control.
Tank capacity: 5,5 liters
Power source: 220-240 V ~50 Hz
6. Assemble the device and store it in a dry place until the next season.
Power: 60W
Water Consumption: 300ml / hour
Power Max: 300W
5. Before season storage clean bottom water tank (6) after unscrewing 3 screws. Then dry water tank, filters and housing to avoid the
moisture damage.
TECHNICAL DATA:
Remote control supplied by lithium type battery CR2025 (3V), included
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Adler AD 7921 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Adler AD 7921 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 4.3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info