800048
6
Zoom out
Zoom in
Previous page
1/100
Next page
6
4. If the dehumidifier is placed in the cabinet, its dehumidifying capacity may highly reduce in a short period after operating due to the
humidity in the cabinet has been highly reduced.
5. For 5°C / 10°C / 15°C /20°C /25°C / 30°C of room temperature and 80% of relative humidity the dehumidifying capacity is respectively
around 2 / 4 / 6 / 8 /10 liters of water when the air outlet is fully open.
Operation
1. Please place the machine unit upright to avoid misoperation and unusual sound.
2. Plug in the device.
3. Press the power switch (1) to turn on the device. The full water tank indication light (10) starts to illuminate continuously. The fan begins
to operate.
4. If the water tank (3) is full or the water tank (3) isn't installed in correct position then, the full water tank indication light (10) starts to
flashing.
5. When the full water tank indicator light (10) is flashing, the compressor installed inside the machine stops so that it does not condense
water until the water tank is empty or set in the correct position, but the fan continues to run.
6. To remove the water tank (3) please do hold the water tank sides and pull out. Look at picture 3.
7. To empty the water tank (3), tilt it as shown at picture 5 and drain the water slowly. Then reinstall the water tank (3) in the dehumidifier.
8. Press the power switch (1) again to turn off the device, the unit machine stops running.
Continuous drainage function
1. If you need to dehumidify the air for a long time, you can use the continuous drainage function.
2. Pull the rubber plug (11), then insert the attached continuous drain hose (7) as on picture 2.
3. After ending the continuous draining, replace the rubber plug (11) and switch off the device.
Continuous drain hose: length: 30 cm, internal diameter: 17 mm, external diameter: 19 mm.
Cleaning and Maintenance
1. Turn off the unit and disconnect the power plug before starting any cleaning or other routine maintenance.
2. To avoid the risk of electric shock, never sprinkle or spill water on the dehumidifier when cleaning.
3. Turn off the unit and empty the water out of the water tank when moving the device. Be sure to hold the handle while moving.
4. Wipe up the dehumidifier with wet cloth (put it into the water and wring it out).
5. Don't dismantle the floater (6) from the water tank (3).
6. Prior to continuous operation for a long duration, periodical checking is required especially for the net air filter (8), the drain hose (7), or
the like.
7. Clean net air filter (8) and filter’s housing (9) every two weeks by vacuum cleaner. Look at picture 4. The dehumidify capacity may
reduce when the filter net is clogged with defilement.
8. Don't clean the device with gasoline, thinner or liquid detergent.
TECHNICAL DATA:
Dehumidify capacity at 30°C / 80% RH): 10 liters / 24 hours
Dehumidify capacity at 27°C / 60% RH): 5 liters / 24 hours
Noise level: <= 45dB
Water tank capacity: 2,2 liters
Air flow: 120 m3 / h
R290 coolant weight: max. 35 grams
Ratted Input Power: 200W
Max. Ratted Input Power: 245W
Power supply: 220-240V ~50Hz Caution, risk of fire.
Do NOT pierce or burn.
Be aware that the refrigerant may not contain an odour.
The maximum refrigerant charge amount: 35g.
WICHTIGE SICHERHEITSHINWEISE SORGFÄLTIG DURCHLESEN UND FÜR DIE
ZUKUNFT AUFBEWAHREN
1. Lesen Sie vor dem Gebrauch des Geräts die Bedienungsanleitung und befolgen Sie
die darin enthaltenen Anweisungen. Der Hersteller haftet nicht für Schäden, die durch
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Adler AD 7917 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Adler AD 7917 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 18.56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info