800047
8
Zoom out
Zoom in
Previous page
1/124
Next page
8
- disconnect the plug and take out the water tank (7),
- remove the grid (13) as shown at picture 6,
- remove the net air filter (12) gently from the filter grid (13),
- clean filter every two weeks with a vacuum cleaner. Run a vacuum cleaner lightly over the surface of the air filter (12) to remove dirt. If the
air filter (12) is exceptionally dirty, wash it with warm water and a mild cleanser and dry thoroughly. Dehumidification performance may
decrease when the filter is clogged with debris.
- put the filter inside the filter grid and assemble them back into the device housing.
8. Don't clean the device with gasoline, thinner or liquid detergent.
9. Storage: when the device is not being used for a long period of time and you want to store it note the following steps:
- Empty any water left in the water tank.
- Fold up the power supply cord (8) and put it inside the water tank (7) inside.
- Clean the net air filter (12).
- Storage in a cool and dry place.
TROUBLE SHOOTING
If a condition listed below occurs, please check the following items before calling customer service.
Problem 1: The device does not operate.
Possible reason 1: Has the power cord been disconnected?
Solution of problem: Plug the power cord into the outlet.
Possible reason 2: Is the full water tank indicator (H) blinking?
Solution of problem: The tank is full or in a wrong position. Empty the water tank (7) and then re-position the tank.
Possible reason 3: Is the temperature of the room above 35 degree of Celsius or below 5 degree of Celsius?
Solution of problem: Built-in protection device is activated and the dehumidifier cannot be started in the temperature of the room above 35
degree of Celsius or below 5 degree of Celsius.
Problem 2: The dehumidifying function does not work
Possible reason 1: Is the net air filter (12) clogged?
Solution problem 1: Clean the air filter as instructed under "Cleaning and Maintenance" – point 7.
Possible reason 2: Is the air inlet (5) or the air outlet (2) obstructed?
Solution of problem: Remove the obstruction.
Problem 3: No air is discharged.
Possible reason 1: Is the net air filter (12) clogged?
Solution of problem: Clean the air filter as instructed under "Cleaning and Maintenance" - point 7.
Problem 4: Operation is noisy
Possible reason 1: Is the device tilted or unsteady positioned?
Solution of problem: Move the device to a stable, even, sturdy surface.
Possible reason 2: Is the net air filter (12) clogged?
Solution of problem: Clean the air filter as instructed under "Cleaning and Maintenance" - point 7.
Problem 5: E1 Code shown on the digital indicator (J)
Possible reason 1: Coil sensor short circuit or open circuit
Solution of problem: Contact the seller who issued you purchase bill.
TECHNICAL DATE:
Dehumidify capacity at 30°C / 80% RH): 10 liters / 24 hours
Noise level: <= 42dB(A)
Water tank capacity: 2.0 liters
Airflow: 150m3/hour
R290 coolant weight: 45 grams
Rated Input Power: 280W
Power supply: 220-240V ~50Hz
Caution, risk of fire.
Do NOT pierce or burn.
Be aware that the refrigerant may not contain an odor.
Device shall be installed, operated and stored in a room with a floor area larger than 4 m.².
The maximum refrigerant charge amount: 45g.
Please transfer cardboard packaging to waste paper. Pour the polyethylene bags (PE) into the plastic container
Worn device should be returned to the appropriate point storage because it is dangerous in the device
ingredients may pose a threat to the environment. The electrical device should be handed over to limit
its reuse and use. If in the device there are batteries you have to take out and give to the point stored separately.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Adler AD 7861 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Adler AD 7861 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 2.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info