642032
4
Zoom out
Zoom in
Previous page
1/12
Next page
Thank you for your decision to purchase this high quality product of ADE Germany. You
bought a scale featuring highest technical standard and well-proven quality. Please read
this instruction manual prior to the start up and keep it careful to have this information on
hand whenever needed.
1. Preparation for use
Activate / Replace batteries:
To replace batteries open the battery cover and move the battery at the recess
downwards and the batteries will be easy to take out. Make sure that you do not bend
the contact. Insert the new batteries and close the battery cover.
Safety guidelines:
Please care that no heavy object may fall on the scale. Otherwise,
the scale may become damage.
Clean the scale only by using a slightly damp cloth. Do not use
solvents or abrasive cleaning agents. Do not submerge the scale
under water. All plastic parts of the scale should been cleaned
immediately after contact with fat, spices, vinegar and other
heavily spiced or coloured food. Avoid contact with citric acid.
2. Handling
Switch-on the scale:
To switch-on the scale push the -key. At first, the LCD display will show all characters
for a few seconds. After the scale levelled off the indication will be0g”. Now the scale is
ready to use.
Units of weight:
By pushing the -key it is possible to change the unit of weight for country specific
setting (g = gram / oz = ounce / lb/oz = fluid ounce / kg = kilogram). Switch-on the scale.
The LCD display will show all characters for a few seconds. Before the display return to
zero, press the -key repeatedly to change the unit of weight. Please pay attention to
use the scale under consideration of your country specific unit of weight.
Tare-func tion:
Use the -key to set the scale to “0”. Place for example a bowl on the weighing platform.
Upon the weight is indicated push the -key to set the indication again to zero. This
process is repeatable until the max. capacity of the scale (5 kg) has been reached. After
removal of the loading, the display indicates the total weight as negative reading.
Automatic- / manua l switch-off the scale
If the indicated weight does not change within approx. two minutes, the scale will
automatically switch-off. To save the battery you can switch-off the scale manually by
pushing the -key for about 2 seconds.
3. Error Messages
Batteries are used up - Please replace the batteries with the
intended type (1 x CR 2032).
O-Ld = Overload - The weight exceeds the maximum capacity of 5 kg.
Please immediately remove the critical load to avoid load cell
damage.
4. Technical Data
Capacity x graduation: max. 5 kg x 1 g
Dimensions: 205 mm x 160 mm x 55 mm
Batteries: 1 x CR 2032 (included)
Subject to technical modifications
5. Warranty
ADE warrants for a period of 3 years from the date of purchase that it will remedy any
defects due to faulty material or workmanship free of charge by repair or replacement.
When purchasing, please have the warranty coupon signed and stamped by the dealer.
When making a guarantee claim, please return the scale together with the guarantee card
including the reason of complaint to your dealer.
2
3
Open the battery cover at the bottom side of the scale and
remove the battery safety strip. Please ensure the correct
polarity of the battery ( +/- ).
=
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ade KE 736 Celina at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ade KE 736 Celina in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info