Thank you for purchasing a high-quality ADE product. Your new scales feature tried-and-
tested quality and meet the highest technical standards.
Please read these Operating Instructions carefully before using the product for the first
time, and keep them in a safe place so that you can consult them again if you need
further information.
1. First use
Inserting the batteries:
Open the lid of the battery compartment on the underside of the scales and insert the
batteries supplied (4 x 1.5V AA). Please ensure the correct polarity of the batteries (+/-).
Safety guidelines:
Ensure that no objects fall onto the scales; otherwise, the scales
may be damaged.
Use only a damp cloth to clean the scales. Never use solvents or
abrasive cleaning agents. Do not immerse in water. If the scale's
plastic parts come into contact with grease, spices, vinegar or
any other strongly spiced or coloured foods, please ensure you
clean them immediately. Keep citric acid away from the scales.
2. Operation
Switching on the scales:
Place the scales on a firm, level surface. Press down on the scales' surface for about
2 seconds with a pressure of 500 g to switch the scales on. The backlighting lights up,
the display shows initially "HI", and once stabilised, will switch to "0 g" or "0: 00 lb oz"
depending on setting. The scales are now ready for use.
Note: If a weight is shown in the display after activation, touch the TARE button to reset
the scales to zero.
Units of weight:
Switch on the scales by touching the TARE button to change the unit of weight
(g <> lb:oz). Touch the TARE button again, when "HI" is displayed. The unit of weight will
now be toggled. Please ensure that the scales are configured to show the unit of weight
that you normally use.
Tare weight function:
Touching the TARE button will set the scales to "0 g". Place e.g. a bowl on the scales,
and touch the TARE button to set the scales back to "0 g". You can repeat this
procedure as often as you like until you reach the scales' max. load capacity (3 kg) is
reached. Once you remove your weighed item(s), the total weight is shown as a minus
value.
Automatic deactivation:
The backlighting of the scales switches off automatically if no weight change is registered
for about 10 seconds. The scales will switch off automatically if no weight change is
registered for about 1 minutes.
3. Error messages
"Lo" = Battery is empty – Please replace the batteries with the appropriate
battery type (4 x 1.5V AA).
"O-Ld" = Overload The 3 kg maximum load capacity has been exceeded.
Remove the object from the scales immediately to avoid damaging the
scales' load cell unit.
4. Technical data
Load capacity x gradation: Max. 3 kg x 1 g
Dimensions: 195 mm x 195 mm x 26 mm
Batteries: 4 x 1.5V AA (included)
Subject to technical changes as a result of product improvements.
5. Warranty
ADE agrees to rectify any material or manufacturing defects by offering free repair or
replacement, for a period of 3 years from the purchase date. At the time of purchase,
please get the retailer to fill in and stamp the guarantee card. In the case of guarantee
claims, please return the scales to your retailer including the guarantee card and stating
the reasons for the claim.
CE conformity
This device is interference-suppressed in accordance with the
applicable EU Directive 2004/108/EC
Note: Extreme sources of electromagnetic radiation, such as those caused by the
operation of radio equipment in the vicinity of the scales, can affect the value displayed.
Once the interference has been eliminated, the product will once again function normally.
Note: the unit may need to be reset.
3
2
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ade KE 1302 Lola at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ade KE 1302 Lola in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info