Thank you for purchasing this high-quality product made by ADE. You have acquired a
set of scales that meet the highest technical standards and are of proven quality.
Please read these operating instructions carefully before using the product for the first
time and keep them in a safe place where you can find them whenever you need the
information contained in the instructions.
1. Putting into service
Activate / Replace batteries:
To replace the battery open the lid of the battery compartment. Move the battery at the
recess downwards. In this way, the battery will be easy to take out. Make sure that you
do not bend the contact. Insert the new battery (1 x CR 2032) and close the lid of the
battery compartment.
Safety information:
Ensure that no objects fall onto the scales; otherwise, the scales
may be damaged.
Only use a damp cloth to clean the scales. Never use solvents
or abrasive cleaners. Do not put the scales under water. You
must clean all the plastic parts of the scales immediately after
they come into contact with grease, spices, vinegar or any other
strongly spiced or coloured foods. Avoid any contact with citric
acid.
2. Operation
Switch-on the scale:
Place the scales on a firm, level base. Switch-on the scales by a short press onto the
ON/TARE/OFF-button at the right side of the scales. At first, the LCD display shows
“8.8.8.8and all symbols. After the scales have stabilised, the indication will be “0 g“.
The scales are now ready to weigh.
Units of weight:
To set the unit of weight (g = gram / lb: oz = pound: ounce / ml = millilitre / fl: oz = fluid:
ounce) switch-on the scales. As soon as the display indicates 8.8.8.8”, shortly press the
ON/TARE/OFF-button repeatedly until the requested unit of weight appears. Please
ensure that the scales are set to the appropriate units of weight for you.
Tare-func tion:
Pressing the ON/TARE/OFF-button allows you to set the scales to "0 g". Place a bowl, for
example, on the platform of the scales, press the ON/TARE/OFF-button and in this way
set the scales back to "0 g". You can repeat this procedure as often as you like until the
total capacity of the scales (5 kg) has been reached. After you remove the item(s) to be
weighed, the total weight is displayed as a minus value.
Automatic - / manua l switch-off the scale:
If the indicated weight does not change within approx. two minutes, the scales will
automatically switch-off. To save the battery you can also manually switch-off the scales
by pressing the ON/TARE/OFF-button for about 2 seconds.
3. Error Messages
“Lo“ = Indication that the battery is flat - Please replace the battery
with the intended type (1 x CR 2032).
EEE E = Overload display - The 5 kg maximum capacity of the scales has
been exceeded. Immediately remove the load from the scales;
otherwise, the load cell could be damaged.
4. Technical Data
Capacity x graduation: max. 5 kg x 1 g
Dimensions: 157 mm x 224 mm x 17 mm
Battery: 1 x CR 2032 (included)
Subject to technical changes due to further-development of the product.
5. Guarantee
ADE guarantees to rectify any defects due to material or manufacturing defects by means
of repair or replacement free of charge for a period of three years. In the case of guarantee
claims, please return the scales together with the sales slip to your retailer and stating the
reasons for the claim.
CE Declaration of Conformity
This device is interference-suppressed in accordance
with the applicable EU directive 2004/108/EC
Note: Extreme electromagnetic influences, e.g. when operating radio communication
equipment is being operated next to the scales, can affect the displayed value. When the
interference is over, you can use the product for its intended purpose again; it may be
necessary to switch it on again.
3
2
Open the lid of the battery compartment on the bottom
of the
scales and remove the battery safety strip
. Please observe the
correct polarity of the batteries (+/-).
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ade KE 1203 Ellen at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ade KE 1203 Ellen in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info