1. Putting into Service
Safety guidelines:
Ensure that no objects fall onto the scales; otherwise, the scales
may be damaged.
Only use a damp cloth to clean the scales. Never use solvents
or abrasive cleaners. Do not put the scales under water. You
must clean all the plastic parts of the scales immediately after
they come into contact with grease, spices, vinegar or any other
strongly spiced or coloured foods. Avoid any contact with citric
acid.
2. Operation
Before using the scales for the first time, or if the balance was stored in the dark, the
memory capacity has to be recharged before use with a light intensity of at least
100 LUX ± 5 LUX as follows:
1
st
. time: charging time 130 sec. / service life 60 sec.
2
nd
. time: charging time 40 sec. / service life 80 sec.
Full charge time: service life 100 sec.
Switching on the scales:
Place the scales on a firm, level base with a light irradiation of at least 100 LUX and wait
until the solar symbol flashes.
The scales are equipped with highly sensitive touch buttons. To switch-on the scales
touch the ON/OFF-button right below the display. The display initially shows at first all
characters. After the scales have stabilised, they display "0 g" or 0.00 oz, depending on
the setting. The scales are now ready to weigh.
Units of weight:
Touching the UNIT-button allows you to change country-specific units of weight
(g = grammes / oz = ounces). Please ensure that the scales are set to the appropriate
units of weight for you.
Tare func tion:
Touching the TARE-button allows you to set the scales to "0 g". Place a bowl, for
example, on the platform of the scales, touch the TARE-button and in this way set the
scales back to "0 g" (is the weight to be tared heavier than 100 g appears next to the
bottom of the display the tare-icon "T. You can repeat this procedure as often as you
like until the total capacity of the scales (5 kg) has been reached. After you remove the
item(s) to be weighed, the total weight is displayed as a minus value.
Automatic- / manua l switch-off the scale
If the indicated weight does not change within approx. 20 seconds, the scales will
automatically switch-off. You can switch-off the scales manually by touching the ON/OFF-
button for approximately two seconds after you have finished using them.
3. Indications
= Sufficient energy available – The scale is ready for use.
EEEE = Overload display The 5 kg maximum capacity of the scales has been
exceeded. Immediately remove the load from the scales; otherwise, the
load cell could be damaged.
4. Technical Data
Capacity x graduation: max. 5 kg x 2 g
Dimensions: 230 mm x 250 mm x 20 mm
Subject to technical changes due to further-development of the product.
5. Guarantee
ADE guarantees to rectify any defects due to material or manufacturing defects by means
of repair or replacement free of charge for a period of three years. When purchasing,
please have the guarantee card signed and stamped by the retailer. When making a
guarantee claim, please return the scales together with the guarantee card to your retailer
and stating the reasons for the claim.
2
3
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ade KE 1130 Helia at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ade KE 1130 Helia in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info