641842
55
Zoom out
Zoom in
Previous page
1/73
Next page
Thank you for your decision to purchase this high quality body analyser scale. Please
peruse read this instruction manual prior to first start up and keep this user instruction
careful so as to have this information on hand whenever it is needed.
1. How does the body analyser work?
Through this new revolutionary scale you will be able to get information about your body
composition with reference to your weight, body fat %, body water % and muscle mass
%. First of all you have to enter once your personal data like gender (male or female and
sports or no sports) body height and age under your selected personal memory location.
Afterwards a measurement is as simple as on a normal bathroom scale. You only have to
push your personal memory location, step on the scale and within a few seconds, your
measured values will be indicated. The analysis is based on the measurement of the
body’ s electrical resistance. A low, safe electrical signal passes freely through fluids
contained in lean tissue, such as muscle and blood, but meets resistance passing
through fat tissue. The body analyser accurately measures the resistance and with
reference to your personal data use it to calculate elements of body composition.
2. How to use
If possible, the measurement should be done undressed but always barefoot.
By nature, a body is subject of fluctuations (for example loss of water after taking
exercise or after a sauna visit, after a meal, etc.). To enable comparable readings it is
important to take the measurements as possible always under the same conditions.
In order to ensure that the results of analysis are accurate and consistent, please keep
the measurement conditions constant always at the same daytime. In the morning,
directly after you ve woken up, your body will be dehydrated and also the majority of fluid
will be stored in the central trunk area. This means that the resistance is relatively high
because of the poor conductivity in the body. By intensify moving during the day
progresses the fluid becomes more evenly distributed through the limbs and increasing
the accuracy of the readings. To get a realistic result it is important to take your readings
at the same time and under the same conditions every day. The easiest way to stick the
rule, measure always in the morning, 15 minutes after you’ ve got up, either before or
after you’ ve gone to the bathroom.
In spite of a very low electrical signal, this body analyser is not suitable for persons
with heart pacemaker or other electronic medical implants! There is no risk for
persons with none electronic implant for instance a titanium plate in the knee. However,
metal conducts the electric current extremely well and therefore the scale implicates the
body fat value beautified means the actual body fat value is higher as indicated.
However, tendencies may be determined as well.
7. Error Messages
---“ = Overload - The weight exceeds the maximum capacity of 180 kg.
Please immediately remove the critical load to avoid load cell damage.
Err2“ = Incorrect weighing / measuring process - For example, the scale is
placed unstable, you do not remain stationary on the weighing platform
or if body fat is less than 5% or higher than 75%.
Lo = Batteries are used up - Please replace the batteries with the intended
type (2 x CR 2032).
8. Technical Data
Capacity x graduation: max. 180 kg x 100 g
Display resolution: body fat: 0.1%
Display resolution: body water: 0.1%
Display resolution: muscle mass: 0.1%
Personal memory locat.: 4 positions
Age: 10 – 80 years
Body height: 100 – 240 cm
Dimensions: approx. 310 mm x 310 mm x 20 mm
Batteries: 2 x CR 2032 (included)
Subject to technical modifications
9. Warranty
ADE warrants for a period of 3 years from the date of purchase that it will remedy any
defects due to faulty material or workmanship free of charge by repair or replacement.
When purchasing, please have the warranty coupon signed and stamped by the dealer.
When making a guarantee claim, please return the weighing scale together with the
guarantee card including the reason of complaint to your dealer.
CE-Conformity - This device features radio interference
suppression in compliance with valid EC Regulation 2004/108
Note: The displayed value may be adversely affected under extreme electromagnetic
influences, e.g. when using a radio unit in the immediate vicinity of the device. Once the
interference has been rectified, the product can once again be used for its intended
purpose. The device may have to be switched on again.
2
7
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ade BA 804 Flora at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ade BA 804 Flora in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info