28
$PNMRX111, Software reset
This message is used to reset the systems. If the message is sent without parameters the
receiver reboots according to the fix procedure (hot, warm or cold) configured with the
PNMRX101 or PNMRX104 messages. A second parameter can optionally be used to specify which
actions are executed after the reset. If the last bit field is set to 1, then the actions are repeated
permanently at each reset, until this bit is cleared.
Field Format Min chars
Max chars
Notes
Message ID $PNMRX111 6 8 PNMRX111 protocol header.
Invalidate parameter
Integer OR
String
1 7 If integer, the bit field have the following meaning
(the action described is executed if the bit is 1):
Field Action
0 Reload settings from Flash
1 Clear almanac data and dont load if from
flash
2 Clear Ephemeris data
3 Clear ionosphere and troposphere
corrections
4 Invalidate stored position
5 Invalidate stored time
6 Copy oscillator offset from Settings
7 Sticky bit –if ‘1’ the action are repeated at
each reset
If String, the following values are allowed:
FACTORY See Section 2.1 for definition.
COLD See Section 2.1 for definition.
WARM See Section 2.1 for definition.
HOT See Section 2.1 for definition.
Checksum *xx (0) 3 3 2 digits.
Message terminator <CR> <LF> 2 2 ASCII 13, ASCII 10.
Examples:
$PNMRX111*xx: Resets the system
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Adapt AD300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Adapt AD300 in the language / languages: English as an attachment in your email.

The manual is 0,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Adapt AD300

Adapt AD300 User Manual - English - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info