INSTALLATION
CONVERSION TO PROPANE
General remarks
According to the indication on the type plate, the water heater is factory preset to operate
with natural gas (G20/G25). Converting the water heater to propane is done through the
addition of an orifice and adjustments. The conversion is prohibited in Belgium.
Set-up conditions
External power supply isolated
Gas supply closed
Upper front panel and top panel of the water heater open, refer to “Removal and Installation of the Front
and Top Panels” on page 39
Procedure of orice installation (WM 25 - 35 - 45 - 70 - 85)
1. Unscrew the gas pipe.
2. Remove the plug from the gas valve (1).
3. Disconnect the air inlet (2) from the venturi (3).
4. Remove the gas valve/venturi assembly by releasing two screws (5). Retain the screws for
reinstallation.
5. Remove the gas valve (1) from the venturi (3) by releasing 3 screws (4). Retain the screws for
reinstallation.
6. Install the orice in the center of the O-ring (6).
Make sure you position the O-ring correctly.
7. Reassemble the gas valve/venturi assembly, following the same procedure in reverse order, and
torque the 3 gas valve screws (4) and the 2 venturi screws (5). Refer to "Torque Values" on page 46.
8. Reinstall the air inlet (2).
Procedure of orice installation (WM 120 )
1. Remove the plugs from the gas valve (1).
2. Unscrew the union (4) of the gas pipe.
3. Release 4 screws from the gas valve ange (3) and retain for reinstallation.
4. Install the orice in the ange (3).
Make sure you position the orifice correctly
(shouldered face turned towards the gas pipe, flat
face turned towards the gas valve).
5. Install the O-ring (2) on the ange.
6. Install the ange (3) on the gas valve (1) using 4 retained
screws.
Follow-on tasks
Stick the sticker provided with the conversion kit on the water heater and check the box to indicate
the type of gas to be now used with the water heater.
Reconnect gas pipe connection.
Reconnect the plug(s) to the gas valve (1).
Restart the appliance.
Change the appliance code through the Installer menu, refer to the “Installer’s handbook
Carry out the CO2 adjustment, (refer to “Checking and Adjusting the Burner on page 42).
Reseal the oset and the throttle on the gas valve (1), as required.
WaterMaster Propane orice dia.
(mm)
25 - 35 - 45 5.2
70 - 85 6.8
120 8.6
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV Watermaster at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV Watermaster in the language / languages: English as an attachment in your email.

The manual is 7.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ACV Watermaster

ACV Watermaster Usermanual and installation guide - German - 48 pages

ACV Watermaster Usermanual and installation guide - Dutch - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info