525509
18
Zoom out
Zoom in
Previous page
1/40
Next page
Smart SL & SLEW
100 - 130 - 160 - 210 - 240
I,
O &
M
Instructions for the User
and the Installer
A1007850 - 661Y1700 • F
Smart SL-SLEW : A1007850 - 661Y1700 • F - draft
Table of Contents
GENERAL RECOMMENDATIONS ...............................................................4
Energy labelling ..................................................................................................................................................... 5
Rating Plate ................................................................................................................................................................ 6
USER'S GUIDE ............................................................................................7
Control Panel (SLEW models only) ......................................................................................................7
APPLIANCE DESCRIPTION ........................................................................8
Models - SL / SLEW 100 - 130 - 160 - 210 - 240 .......................................................................................... 8
TECHNICAL CHARACTERISTICS .............................................................10
Dimensions and Main Characteristics ............................................................................................10
Electrical Characteristics .............................................................................................................................12
Performance ............................................................................................................................................................ 14
INSTALLATION .........................................................................................15
Safety Instructions ............................................................................................................................................. 15
Packing Contents ...............................................................................................................................................17
Tools ................................................................................................................................................................................ 17
Tank Installation : SL 100 - 130 - 160 -210 - 240 .....................................................................18
Tank Installation : SLEW 100 - 130 - 160 - 210 - 240 ..........................................................19
G3 Requirements and Guidance .........................................................................................................20
Connection ...............................................................................................................................................................24
SLEW tank used as electric DHW tank only .............................................................................27
Available Kits and Accessories .............................................................................................................27
Smart SL-SLEW: A1007850 - 661Y1700 • F - draft
Table of Contents
STARTING UP ...........................................................................................28
Safety Instructions to Fill the Tank .....................................................................................................28
Filling ..............................................................................................................................................................................29
Checks before Starting up ......................................................................................................................... 31
MAINTENANCE ........................................................................................32
Periodic Checks by the User ...................................................................................................................32
Annual Maintenance .......................................................................................................................................32
Draining .......................................................................................................................................................................33
Bringing back into Service after Maintenance .......................................................................34
Replacement of the Electric Heating Element (SLEW tank) ....................................... 35
Fault Finding ...........................................................................................................................................................36
3
EN
We accept no liability should any damage result from the failure to comply with theins-
tructions contained in this technical manual.
Essential recommendations for safety
It is strictly prohibited to carry out any modifications to the appliance without
the manufacturer’s prior and written agreement.
The product must be installed by a qualified engineer, in accordance with
applicable local standards and regulations.
The installation must comply with the instructions contained in this manual and
with the standards and regulations applicable to domestic hot water tanks.
Failure to comply with the instructions in this manual could result in personal
injury or a risk of environmental pollution.
The manufacturer declines all liability for any damage caused as a result of
incorrect installation or in the event of the use of appliances or accessories that
are not specified by the manufacturer.
Essential recommendations for the correct operation of the appliance
In case of anomaly, please call your installer for advice.
Faulty parts may only be replaced by genuine parts.
Our water heaters are designed and manufactured for the exclusive purpose of
heating and storing domestic hot water.
The domestic hot water heaters must only be heated using hot water in a closed
circuit.
General remarks
The availability of certain models as well as their accessories may vary according
to markets.
The manufacturer reserves the right to change the technical characteristics
and features of its products without prior notice. Please check for an updated
version of this manual on the website www.acv.com.
The part number (P/N) and serial number (S/N) of the appliance are indicated on
its rating plate and must be provided to ACV in case of warranty claim. Failure
to do so will make the claim void.
In spite of the strict quality standards that ACV applies to its appliances during
production, inspection and transport, faults may occur. Please immediately
notify your approved installer of any faults.
NOTES
This manual contains important information with respect to the installation, the starting up
and the maintenance of the appliance.
This manual must be provided to the user, who will read it carefully and keep it in a safe
place.
Smart SL-SLEW : A1007850 - 661Y1700 • F - draft
G R
EN
4
ENERGY LABELLING
Smart SL-SLEW: A1007850 - 661Y1700 • F - draft
P I
5
EN
Smart SL-SLEW : A1007850 - 661Y1700 • F - draft
Product Information
RATING PLATE
EN
6
Smart SL-SLEW: A1007850 - 661Y1700 • F - draft
U' G
Key :
1. Control thermostat [60/8C] - To set the domestic hot water (DHW) temperature.
2. Fuse FF 12,5 Amp - To provide an electric protection to the appliance.
3. Summer / Winter switch - To activate the heating pump of the heating system/deacti-
vate the electrical heating element ( - winter position) or activate the electrical heating
element/deactivate the heating system pump ( - summer position).
4. Heating-element-on indicator - The built-in indicator lights when the heating element is
activated ( position of the summer / winter switch).
CONTROL PANEL SLEW models only
7
EN
1
2
3
4
Heating
element ON
Heating
element OFF
Smart SL-SLEW : A1007850 - 661Y1700 • F - draft
A D
SL 100 - 130 - 160 - 210 - 240
EN
8
1
2
10
4
5
6
7
8
9
11
12
14
15
13
8
3
MODELS  SL / SLEW 100 - 130 - 160 - 210 - 240
SL : Storage water tanks, to be installed on the floor or either vertically or
horizontally on the wall, that work within a heating system.
SLEW : Storage water tanks, to be installed vertically on the wall, that can work within a
heating system, or independently as an electric domestic hot water heater. The
SLEW tank is equipped with one 2200 W heating element controlled by the
thermostat and by the Summer/Winter switch on the appliance control panel.
Smart SL-SLEW: A1007850 - 661Y1700 • F - draft
Appliance Description
SLEW 100 - 130 - 160 - 210 - 240
1. Auxiliary connection DHW
2. Cold water inlet connection
3. Control thermostat
4. Flow connection (primary circuit)
5. Polyurethane foam insulation
6. Return connection (primary circuit)
7. Outer steel tank (primary circuit)
8. Manual air bleed valve (x 2 - SL Mod-
els)
9. Hot water outlet connection
10. Polypropylene top lid
11. Stainless steel tank (DHW)
12. Polypropylene shell
13. Polypropylene bottom lid
14. DHW thermometer
15. Dry well
16. Control panel
17. 2200 W electric heating element
9
EN
1
2
4
9
6
7
8
5
10
11
12
13
16
17
14
15
3
Smart SL-SLEW : A1007850 - 661Y1700 • F - draft
T C
DIMENSIONS AND MAIN CHARACTERISTICS
Tank dimensions SL / SLEW
100 130 160 210 240
A mm 865 1,025 1,225 1,497 1,744
B mm 629 789 989 1,261 1,508
C mm 365 525 725 997 1,244
Empty weight Kg 49 55 65 75 87
EN
10
A
B
264
C
360
325
295
145
565
AB
264
C
360
325
295
145
565
SL
A
B
264
C
565
360
325
295
145
A
B
264
C
565
360
325
295
145
SLEW
Smart SL-SLEW: A1007850 - 661Y1700 • F - draft
Technical Characteristics
Main characteristics
SL/SLEW
100 130 160 210 240
Total capacity L 105 130 161 203 242
Primary capacity L 30 31 35 39 42
DHW capacity L 75 99 126 164 200
Primary connection [F] " 1 1 1 1 1
DHW connection [M] " 3/4 3/4 3/4 3/4 3/4
Auxiliary DHW loop connection [M] " 3/4 3/4 3/4 3/4 3/4
Primary pressure drop* mbar 22.6 26.8 26.8 41.6 47.3
Heating surface area 1.03 1.26 1.54 1.94 2.29
Max Design Pressure* bar 10 10 10 10 10
SL
100 130 160 210 240
Reheat Performance - Primary
Heating Power Input* kW 18.4 24.7 32.2 39.2 44.6
Primary ow rate (to achieve Reheat
Performance) * L/sec. 0.7 0.7 0.7 1.25 1.25
Reheat time* min 10 10 10 9 9
Standing Heat Loss* kWh/24h 0.86 0.96 1.13 1.27 1.37
W 36 40 47 53 57
SLEW
100 130 160 210 240
Reheat Performance - Primary
Heating Power Input* kW 18.4 24.7 32.2 39.2 44.6
Primary ow rate (to achieve Reheat
Performance) * L/sec. 0.7 0.7 0.7 1.25 1.25
Reheat time* min 10 10 10 9 9
Standing Heat Loss* kWh/24h 0.91 1.01 1.18 1.3 1.42
W 38 42 49 54 59
* According to EN12897:2006
11
EN
Smart SL-SLEW : A1007850 - 661Y1700 • F - draft
Technical Characteristics
Main characteristics SL
100 130 160 210 240
Rated voltage V~ 230 230 230 230 230
Rated frequency Hz 50 50 50 50 50
Max. Amp rating A 6 6 6 6 6
ELECTRICAL CHARACTERISTICS
Wiring diagram
1. 230 Volt supply cord
2. Control thermostat [60/80°C]
3. Manual reset high limit thermostat [89°C max.]
4. Summer / Winter switch
5. Fuse FF 12,5 A
6. Electric heating element
7. Charging pump [option]
8. Heating-element-on indicator
B. Blue
Bk. Black
Br. Brown
G. Grey
Or. Orange
W. White
Y/Gr. Yellow/Green
EN
12
Br
Y/Gr
B
Br
Br
Y/Gr
BB
N L1
NL1
SLE W
6
BBk
t
c
1
2
t
2
3
5
4
B
BB
G
W
Or
Bk
c1
2
SL
Br
Y/Gr
B
OrOr
Y/Gr
Bk
Bk
N L1
L1 N
t
2
7
SL
Smart SL-SLEW: A1007850 - 661Y1700 • F - draft
Technical Characteristics
Main characteristics SLEW
100 130 160 210 240
Rated voltage V~ 230 230 230 230 230
Rated frequency Hz 50 50 50 50 50
Electrical consumption with
electrical heating element W 2,200 2,200 2,200 2,200 2,200
Rated current with electrical
heating element A 10 10 10 10 10
13
EN
c
2 1
t
t
L1 PE N
M
T1
T2
Br Bk
Or
W
B
Y/Gr
B
Y/Gr
B
B
Gr Br
BB
Bk B
Bk
7
3
2
4
5
6
230 V ~50Hz
B
Y/Gr
Br
1
8
SLEW
Smart SL-SLEW : A1007850 - 661Y1700 • F - draft
Technical Characteristics
PERFORMANCE
DHW performance* SL / SLEW
100 130 160 210 240
Peak ow at 40 °C L/10' 236 321 406 547 700
Peak ow at 60 °C L/10' 117 161 209 272 337
Peak ow rst hour at 40 °C L/60' 784 1,063 1,349 1,820 2,319
Peak ow rst hour at 60 °C L/60' 384 549 689 913 1,165
Constant ow at 40 °C L/h 658 890 1,132 1,527 1,943
Constant ow at 60 °C L/h 320 465 576 769 994
Power drawn kW 23 31 39 53 68
Initial heating time Minutes 24 22 22 20 20
SLEW ONLY
Heating time with the 2.2 kW
heating element from 10 to 60°C 2 h 43' 3 h 27' 4 h 20' 5 h 37' 6 h 37'
Conditions: Primary circuit temp.: 85°C, water supply temp.: 10°C
Maximum Operating Conditions SL / SLEW
100 130 160 210 240
Max. operating pressure - primary bar 3 3 3 3 3
Max. operating pressure - DHW bar 8.6 8.6 8.6 8.6 8.6
Supply pressure (DHW circuit) bar 6 6 6 6 6
Maximum temperature - heating side °C 90 90 90 90 90
Maximum temperature - DHW side °C 80 80 80 80 80
Water quality
Chlorides < 150 mg/L
6 ≤ pH ≤ 8
If hardness > 20°fH, water softener recommended.
EN
14
SAFETY INSTRUCTIONS
General remarks
Connections (electrical, hydraulic) must be carried out in accordance with
applicable standards and regulations.
If the water drawing off point is far from the tank, installing an auxiliary DHW
loop can allow to get hot water more quickly at all times.
Essential instructions forthecorrect operation ofthesystem
The tank must be installed in a dry and protected area.
Install the appliance to ensure easy access at all times.
To avoid any risk of corrosion, connect the stainless steel tank directly to the
earth. Use an adjustable earth clamp (see example below) on one of the DHW
connections to connect to the earth. Advised copper wire section: 2.5mm².
Make sure to install a pressure reducing valve set at 4.5 bar in the DHW circuit
if the supply pressure is higher than 6 bar.
On the DHW circuit, install an approved safety group, comprised of a safety
valve set at 7 bar, a check valve and a stop valve.
Make sure that the outlet of the safety unit goes directly to the sewer to avoid
any potential damage.
Do not install the safety group above the tank to avoid water discharge on to
the tank.
Smart SL-SLEW: A1007850 - 661Y1700 • F - draft
en
15
I
15
EN
Essential instructions forthe safety of persons and the environment
Hot water can burn!
In the event of small amounts of hot water repeatedly being drawn off, a
stratification effect can develop in the tank. The upper hot water layer may
then reach very high temperatures.
ACV recommends using apre-set thermostatic mixing valve in order to provide
hot water at a maximum of 6C.
Water heated to wash clothes, dishes and for other uses can cause serious
burns.
In order to avoid exposure to extremely hot water that can cause serious burns,
never leave children, old people, disabled or handicapped people in the bath
orshower alone.
Never allow young children to turn on the hot water or fill their own bath.
Adjust the water temperature in accordance with usage and plumbing
regulations.
The risk of developing bacteria exists, including “Legionella pneumophila”,
if a minimum temperature of 60°C is not maintained in both the DHW tank
andthe hot water distribution network.
Essential instructions for the electrical safety
Only an approved installer is authorized to carry out the electrical connections.
Make sure that the appliance is connected to the earth.
Install a 2-way switch and a fuse or circuit breaker of the recommended rating
outside the appliance, so as to be able to shut power down when servicing the
appliance or before performing any operation on it.
Shut down external electrical supply of the appliance before performing any
operation on the electrical circuit.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless supervised or unless they have been given instruction
concerning the use of the appliance by a person responsible for their safety.
Smart SL-SLEW : A1007850 - 661Y1700 • F - draft
Installation
EN
16
Smart SL-SLEW: A1007850 - 661Y1700 • F - draft
Installation
Package
One SL/SLEW hot water tank.
One multilingual Installation, Operation and Maintenance Instructions.
One wall-mounting kit with support and ow diverter
One energy label
PACKING CONTENTS
All appliances are delivered, tested and packaged separately.
General Remark
The hot water tank may be installed either on the floor or on a wall using
the provided wall-mounting kit (depending on the model).
Essential instructions for the correct operation of the installation
When hung on a wall, the SLEW models must be assembled with the
heating element to the bottom (DHW pipes to the bottom).
In horizontal configuration (SL only), the peak output and the first hour
continuous output will be reduced. In this case, we recommend to
oversize the tank.
TOOLS
17
EN
Smart SL-SLEW : A1007850 - 661Y1700 • F - draft
Installation
Vertical wall hung position : domestic water connections at the bottom side
12
Horizontal wall hung position : domestic water connections on the right side
12
ACV does not recommend the installation in a horizontal position, as it will increase
heat-up time and reduce DHW performances.
CH flow rate > 2000 l/h CH flow rate ≤ 2000 l/h
CH in
Air vent
Flow diverter
TANK INSTALLATION : SL 100  130  160 210  240
Floor mounting
EN
18
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV SLE W 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV SLE W 100 in the language / languages: English as an attachment in your email.

The manual is 2.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ACV SLE W 100

ACV SLE W 100 User Manual - German - 36 pages

ACV SLE W 100 User Manual - Dutch - 36 pages

ACV SLE W 100 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info