PRESET CONFIGURATION 1  PRESTIGE SOLO/EXCELLENCE 3WAY VALVE
DHW
CH1
CH2
Prestige
P3
P4
Two heating circuits, with two room thermostats and optional outdoor sensor,
and with DHW circuit.
Electrical board terminals Terminal name --> Connected to
ACV Max
123456
1 2 3 4 5 6
W
W
W
W
W
W
4 5 6
1 2 3
1 2 3
4 6
X15
1 2 3 4 5 6 7 8 9 10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X11
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
16
15
3 4
1 2
X16
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
W
R
Or
Bk
Bk
V
Bk
42 1 3 2 1 1 2 3 1 2 3 4 5 6
8 9 10 11 12
1 2 3 4 5
13
6
14
7
X2
1 2 3 4 5 6 7 8 9 10
W
R
Y
R
Y
BK
BK
W
6 7 8 9 10
1 2 3 4 5
X3
1 2 3 4 5 6 7 8 9 10 11 12
V
W
R
Bk
7 8 9 10 11
1 2 3 4 5
12
6
X1
R
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Y
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
V
1 2 3 4 5
1 2 3 4 5
8
Bk
2 31
1412 13
X12
X9
P14
123
4
123
456
B
V
B
W
P13
B
Or
123
Bk
B
Y/Gr
W
Br
B
Br
Br
Y/Gr
B
B
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
123
5
F00
X100
N
L
N
L
W
ON / OFF
3
230 V ~ 50Hz
1
N
L
N
L
N
L
2
6
B
Y/Gr
Br
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
V
B
Y/Gr
W
B
Y/Gr
Br
B
Y/Gr
Br
B
Y/Gr
B
Or
Br
B
Br
Y/Gr
B
X101
18
17
20
19
21
24
4
X10
12
X20
16
25
2 1
1
NTC 5
9
2 1
1
NTC 2
10
2 1
1
NTC 1
11
123
1
21234123456
X7
X4
X6
X5
Bus A
Bus - Ground
Bus B
0-10 Volt - Ground
0-10 Volt - Input
Cascade sensor - Ground
Cascade sensor - Input
NTC 3
NTC 4
1
2
22
23
26
X18
V
W
B
W
B
B
9 10 11 12 13 14 15 16
16 15 14 13 12 11 10 9
X100
7
Y/Gr
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4 P3
FL
27
5AT Fuse
5AT Fuse
5AT Fuse
............. ERR --> Error (Alarm)
............. DHW --> None
............. CH --> Built-in circulator pump
............. P4 --> P4 pump (CH2 circuit)
............. Flame --> Flame sensor
............. P3 --> P3 pump (CH1 circuit)
ACV Max
1 2 3 4 5 6
W
W
W
W
W
W
B
Br
4 5 6
1 2 3
1 2 3
4 6
1 2 3 4 5
X15
1 2 3 4 5
1 2 3 4 5 6 7 8 9 10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X11
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
18
17
3 4
1 2
X16
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
W
R
Or
Bk
Bk
Or
Bk
4 3 2 1 1 2 3 1 2 3 4 5 6
8 9 10 11 12
1 2 3 4 5
13
6
14
7
X2
1 2 3 4 5 6 7 8 9 10
W
R
Y
R
Y
W
6 7 8 9 10
1 2 3 4 5
X3
1 2 3 4 5 6 7 8 9 10 11 12
V
W
Br
R
Br
Or
B
W
R
Bk
7 8 9 10 11
1 2 3 4 5
12
6
X1
Bk
2 31
1615
X12
X9
P14
12
X10
12 3
4
123
456
B
B
V
B
W
W
B
B
P13
B
Or
123
Bk
B
Y/Gr
W
Br
B
Br
Y/Gr
B
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
123456
123
5
F00
X100
W
ON / OFF
3
230 V ~ 50Hz
1
2
6
26
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
V
B
Y/Gr
W
B
Y/Gr
Br
B
Y/Gr
Br
B
Y/Gr
B
Or
Y/Gr
19
21
20
22
23
24
4
B
W
V
Br
X20
25
X18
STEPPER
PUMP PWM
8
9
5AT Fuse
5AT Fuse
5AT Fuse
R
Bk
Y
Y
R
R
W
W
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
W
Or
Br
R
Br
B
Br
B
Y/Gr
V
1 2 3 4 5
1 2 3 4 5
10
A B C D 2 1
1
NTC 5
11
2 1
1
NTC 2
12
2 1
1
NTC 1
13
26
C
M
M
3 2 1 3 2 1
230 V
Bk
Bk
14
Bk
Bk
123
1
21234123456
X7
X4
X6
X5
Bus A
Bus - Ground
Bus B
0-10 Volt - Ground
0-10 Volt - Input
NTC 3
NTC 4
1
2
V
W
B
W
B
B
9 10 11 12 13 14 15 16
X100
7
Y/Gr
Y/Gr
16 15 14 13 12 11 10 9
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4 P3
FL
230 V
............. DHW sensor (NTC3)
............. Optional outdoor temp. sensor (NTC4)
............. Optional room thermostat 1
............. Optional room thermostat 2
ACV Max
123456
1 2 3 4 5 6
W
W
W
W
W
W
4 5 6
1 2 3
1 2 3
4 6
X15
1 2 3 4 5 6 7 8 9 10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X11
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
16
15
3 4
1 2
X16
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
W
R
Or
Bk
Bk
V
Bk
42 1 3 2 1 1 2 3 1 2 3 4 5 6
8 9 10 11 12
1 2 3 4 5
13
6
14
7
X2
1 2 3 4 5 6 7 8 9 10
W
R
Y
R
Y
BK
BK
W
6 7 8 9 10
1 2 3 4 5
X3
1 2 3 4 5 6 7 8 9 10 11 12
V
W
R
Bk
7 8 9 10 11
1 2 3 4 5
12
6
X1
R
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Y
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
V
1 2 3 4 5
1 2 3 4 5
8
Bk
2 31
1412 13
X12
X9
P14
123
4
123
456
B
V
B
W
P13
B
Or
123
Bk
B
Y/Gr
W
Br
B
Br
Br
Y/Gr
B
B
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
123
5
F00
X100
N
L
N
L
W
ON / OFF
3
230 V ~ 50Hz
1
N
L
N
L
N
L
2
6
B
Y/Gr
Br
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
V
B
Y/Gr
W
B
Y/Gr
Br
B
Y/Gr
Br
B
Y/Gr
B
Or
Br
B
Br
Y/Gr
B
X101
18
17
20
19
21
24
4
X10
12
X20
16
25
2 1
1
NTC 5
9
2 1
1
NTC 2
10
2 1
1
NTC 1
11
123
1
21234123456
X7
X4
X6
X5
Bus A
Bus - Ground
Bus B
0-10 Volt - Ground
0-10 Volt - Input
Cascade sensor - Ground
Cascade sensor - Input
NTC 3
NTC 4
1
2
22
23
26
X18
V
W
B
W
B
B
9 10 11 12 13 14 15 16
16 15 14 13 12 11 10 9
X100
7
Y/Gr
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4 P3
FL
27
5AT Fuse
5AT Fuse
5AT Fuse
CH & DHW Settings
Boiler Settings
Boiler Settings
Prestige Model Solo/Excel. 3way valve
Lockout Temp. 105°C
Modbus Address 1
Pump settings
Ignition Level 3100rpm
Pump Settings
Current Pump Cong Solo/Excellence 1
Preset Pump Cong
Flexible Pump Cong
ACCESSING THE PRESET CONFIGURATION PAGE FOR THE SOLO/EXCEL.
(3-WAY VALVE)
To access the preset conguration page, follow the selections shown on the screens below (Installer menu)
Pump Conguration 1
Flex 4
ERR
Flex 6
P4
Flex 3
P3
Flex 2
DHW
Flex 1
CH
Flex 5
Flame
Error CH2 CH1 CH1/CH2/
DHW
Flame
In the following hydraulic diagrams, this representation is used :
Warm water
Cold water
Preset Pump Cong
Solo / Excellence 1
Solo / Excellence 2
Solo / Excellence 3
Solo / Excellence 4
Do not forget to select the correct
boiler in the Boiler Settings, Prestige
Model.
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV Prestige at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV Prestige in the language / languages: English as an attachment in your email.

The manual is 13,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info