CH & DHW Settings / Heating Settings (Cont’d)
Heating Settings
CH1 Max. Setpoint 82°C
CH1 Min. Setpoint 49°C
Outdoor Curve / Coldest Day -12°C
Outdoor Curve / Warmest Day 18°C
CH2/CV2 Circuit Enabled
CH2 Max. Setpoint 60°C
Heating Settings
CH1 Min. Setpoint 49°C
Outdoor Curve / Coldest Day -12°C
Outdoor Curve / Warmest Day 18°C
CH2/CV2 Circuit Enabled
CH2 Max. Setpoint 60°C
CH2 Min. Setpoint 27°C
CH2 Min.
Setpoint
27°C
15°C 60°C
CH2 Minimum Setpoint is the minimum setpoint for a CH2 heating call when an Out-
door Curve option is chosen in Demand Type. This setting is not applicable when a Set-
point option is chosen in Demand Type.
Press the LEFT or RIGHT buttons to adjust the CH2 Minimum Setpoint then press the OK
button to store the setting.
Default: 27°C
Heating Settings
Outdoor Curve Coldest Day -12°C
Outdoor Curve Warmest Day 18°C
CH2/CV2 Circuit Enabled
CH2 Max. Setpoint 60°C
CH2 Min. Setpoint 27°C
Warm Weather Shutdown
O
Warm Weather Shutdown
O
O 25°C
Warm Weather Shutdown allows to enter an optional outdoor temperature at which to disa-
ble the central heating function. The Prestige will continue to respond to a domestic hot water
call or a 0- 10V Modulation Signal when the outdoor temperature exceeds the Warm Weather
Shutdown Temperature setting.
Press the LEFT or RIGHT buttons to adjust the Warm Weather Shutdown Temperature then
press the OK button to store the setting and complete the Heating setting.
The Warm Weather Shutdown icon (
) is displayed on the home screen when the outdoor
temperature reaches the Warm Weather Shutdown Temperature.
Default: OFF.
Heating Settings
Outdoor Curve / Warmest Day 18°C
CH2/CV2 Circuit Enabled
CH2 Max. Setpoint 60°C
CH2 Min. Setpoint 27°C
Warm Weather Shutdown
O
Circulation Pump Permanent Disabled
Circulation Pump
Permanent
Disabled
Enabled
Circulation Pump Permanent allows the central heating circulators to be con-
stantly enabled even without a central heating call. A domestic hot water call
will cause the circulators to be disabled during the domestic call as long as DHW
Priority is enabled.
Press the UP or DOWN buttons to select Enabled or Disabled then press the OK
button to store the setting.
EnabledThe central heating circulators will be enabled for constant circu-
lation without a central heating call.
DisabledThe central heating circulators will only be enabled during a cen-
tral heating call.
Default: Disabled
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV Prestige Solo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV Prestige Solo in the language / languages: English as an attachment in your email.

The manual is 13,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info