The temperatures of typical heat pump cycles, in connection with features of the cooling fluid and the
free source ensure heating of sanitary water located in the aluminium pipe heat exchanger placed outside of
HB300(C) heat pump water heater up to a temperature of max. 60°C, besides normal usage conditions. As
HB300(C) heat pump water heater has been equipped with a supplementary pipe radiator that provides further
options: quicker obtaining of operation with full capacity through combination of heat pump mode and pipe
radiator mode up to a temperature of max. 60°C that may be used after running of antibacterial protective
cycles. In order to ensure rational energy use during the operation of the hot water tank, visual indicators call
the attention of the user on the fact that the appliance is not operated in the most efficient way if the pipe
radiator is active.
2.3. Water heating methods
The appliance (in case of HB300C type) integrates heating elements that contain a heat pump, an electric pipe
radiator and a heat exchange pipe coil. Heating elements do not operate all the three in the same time. Hot water
tanks of HB300C type can be operated from several different energy sources: indirectly from solar energy, or
gas-based, coal-based or other based energy carriers, furthermore, auxiliary electric heating provided by
appliances of HB300(C) type is controlled by the heat pump unit.
This appliance possesses two temperature-sensors that are placed in the upper flare located in the
closing cover and in the lower flare. The sensor placed in the upper flare measures upper temperature and this
number is displayed by the Water temp indicator, while the sensor placed in the lower flare monitors the lower
temperature, which serves as input data for switch on/ off, but this is not displayed at all.
1.) Economy Mode:
In this mode, it is the heat pump that is working, not the electric heater as a result of pre-set water
temperature.
(The water outlet temperature is between 38~60C, the operation environment temperature is between -7~43C)
2.) Hybrid Mode:
In this mode, the equipment is sharing its operation capabilities between electric heating and heat pump,
based on the temperature of the water tank.
(The water outlet temperature is between 38~60C, the operation environment temperature is between -30~43C)
3.) E-heater Mode:
In this mode, the motors of the compressor and the fan are not working, only the electric heater is working. This time, only water
located in the upper part of the tank is heated, which means. approximately 100 l.
(The water outlet temperature is between 38~60C, the operation environment temperature is between -30~43C)
a) Defreezing through water heating
In case of Economy Mode and Hybrid Mode, if the evaporating steam freezes in cold environment, the
appliance defreezes it automatically, to ensure efficient performance (3~10 min).
b) External environmental temperature
The operation temperature of the appliance should be within the interval -30~43 C and the operation
temperatures of the modes are described below in details.
2.4. Explanation of water heating operation
1) Economy Mode: -7~43C
This mode is recommended when the external environmental temperature is between -7~43C . If the
external environmental temperature falls under the temperature of -7C, energy efficiency becomes low,
evidently, thus it is recommended to use E-heating mode under these circumstances.
2) Hybrid Mode: -30~43C
3) E-heater Mode: -30~43C
In each case, only water located in the upper part of the tank is heated, which means. approximately 100
2.5 Mode selection
As different modes have been developed to serve different needs, it is recommended to consider the following: .
Economy Mode:-7~43C,
In case of continuous hot water need under 300 L (60 C);
Hybrid Mode: -30~43C,
In case of continuous hot water need between 300 L (60C).
E--heater Mode: -30~43C,
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV HP300C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV HP300C in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 2,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info