524653
4
Zoom out
Zoom in
Previous page
1/26
Next page
ENFRRU PL DE IT ES NL
EN • 4
664Y5400B
USER'S GUIDE
USING THE BOILER
Make sure to have your installation inspected and
maintained, if required, at least once a year by an
approved and qualified engineer. More frequent
servicing may be required depending on boiler use. If
this is the case, consult your installer for advice.
Starting the burner:
In normal operation, the burner starts automatically
as soon as the boiler temperature drops below the set
temperature.
GETTING FAMILIAR WITH THE CONTROL PANEL
The user must not attempt to gain access to the components inside the
control panel.
• Master switch
Is used to turn the HeatMaster® on or off.
• Control thermostat - 60-90 °C
When using the HeatMaster® as a hot water generator only, the
temperature can be set between 60 °C and 90 °C. If the HeatMaster®
is used for both domestic hot water (DHW) and central heating, the
control thermostat would normally be set at 80 °C to achieve optimum
operating conditions.
• Summer/winter switch
Is used to turn the heating pump (if fitted) on or off.
• Manual reset high limit thermostat
If the boiler temperature exceeds 103 °C, this safety device will activate
and the high temperature indicator will light up. To reset - first allow the
boiler to cool to below 60 °C, unscrew the cap and press the reset button
using a pencil or similar pointed device, then reinstall the cap. If the fault
persists, turn the boiler off and call a service engineer.
• Daily timer
Allows the HeatMaster® to be turned on and off at specific moments of
the day and operates on a 24 hour sequence. A series of white tabs are
set around the timer, each tab corresponding to a 15 minute switching
period. To set the timer, simply push outwards the number of tabs
required for ON period.
Remember: Tab in = HeatMaster® OFF
Tab out = HeatMaster® ON
• Temperature and pressure gauge
This gauge indicates both the temperature of the HeatMaster® and the
pressure within the primary circuit. The temperature should not exceed
90 °C - if it does, switch the boiler off and check the thermostat setting.
If the fault persists, call an engineer. The pressure should not fall below
1 bar, if it does, please see the ‘Heating System Pressure’ paragraph
further in this section.
• Low primary water pressure indicator
If this indicator lights up, the primary circuit of the HeatMaster®
requires topping up with water. Please see the ‘Heating System
Pressure’ paragraph later in this section.
1. Burner safety cutout warning indicator
2. Low primary water pressure indicator
3. High limit thermostat indicator
4. Temperature and pressure gauge
5. Control thermostat
6. Daily timer
7. Manual reset high limit thermostat
8. Master switch
9. Summer/winter switch
HeatMaster® 30 N and 60 N Control Panel
I
O
1
4
53
2
76
8 9
HeatMaster® 70 N and 100 N Control Panel
I
O
1
4
53
2
76
8 9
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV HEATMASTER 30 N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV HEATMASTER 30 N in the language / languages: English as an attachment in your email.

The manual is 8,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ACV HEATMASTER 30 N

ACV HEATMASTER 30 N User Manual - German - 26 pages

ACV HEATMASTER 30 N User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info