677365
15
Zoom out
Zoom in
Previous page
1/28
Next page
14
DEAR USER!
We ask you to read this installation and operation manual by paying much attention before using
the appliance.
The electric connection, the connection to the water network and the first starting up must be
realised by your installation technician. The appliance is not a toy. It must not be used by persons
with physical, mental or sensorial handicap (including children) and by persons without enough
experience.
Such persons may use the appliance in presence of a person taking care of their security or by
following their instructions.
Do not leave children without attendance and you should make sure that they do not play with the
appliance.
Before fixing the boiler to the wall, verify that the wall can bear the weight of the
appliance filled up with water.
CONNECTION TO THE WATER NETWORK
In the case of hydraulic connection to a
water system made of brass, it is
compulsory to use reduced dielectric sleeves
or equal male-female sleeves made of
malleable cast iron. Should the thread of the
tubes, which are not provided with such
sleeves, be attacked by corrosion, our
guaranty cannot be applicable.
The hot water-cold water connection of the
appliance should be realised by following the
diagram in fig. 1 (drawing of the boiler +
safety group) and in compliance with the
applicable legal regulations. Do not expose
the boiler to pressure exceeding 7 bars in
any case otherwise the appliance will suffer
irreparable damages. Recommended safety group: safety group of 6 bars manufactured by
RITMONIO Company, matching the tube connection of the appliance.
1. It is compulsory to mount a safety group complying with the standards to the cold water inlet of
the appliance. This combined group contains a check valve and a safety valve. This safety
valveopens where the pressure increases to 6.3 - 7 and closes at 6 bars, in addition, it has a
stopcock.
2. The discharge pipe at the outlet of the appliance should be put to a place protected from freeze,
for insuring free flow.
Strictly follow the installation diagram because the good functioning of the boiler depends on it.
3.
If the operating pressure exceeds 6 bars, a pressure reducer must be mounted in front of the
safety group.
4. If one or several mixing faucets are used, a check valve is to be mounted to the cold water
column supplying the mixing faucets.A stopcock has to be placed on the cold water supply of the
appliance.
5.
The safety group may leak, therefore the drain pipe must not be obstructed!
6. The safety group is not an accessory of the appliance.
FUNCTIONING
This closed-system appliance is intended to
produce hot water in households and institutions.
The hot water can be used for both sanitary and
consumption purposes .
The water temperature of the boiler can be
adjusted depending on your needs (65 °C).
After having achieved the adjusted or preferred
temperature, the temperature regulator switches
off the heating automatically. In this way there is
hot water in the boiler for a long time. The
polyurethane insulation in the internal tank
prevents the fast cooling of the hot water,
therefore, the water remains hot for a long time.
Hot water flows out without mixing with cold
water.
ENG
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV Glass ST 2014 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV Glass ST 2014 in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 5,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info