101,6 mm
101,6 mm
48,4 mm
48,4 mm
763 mm
763 mm
442 mm
332 mm
185 mm
370 mm
105 mm
E-Tech W : 664Y6500 • B
en
10
EN
FR
NL
ES
IT
DE
PL
RU
INSTALLATION
DIMENSIONS
Min.
25 mm
Min.
400 mm
Min.
200 mm
WALL MOUNTING
The boiler must be fixed to a non flammable
wall.
Observing the clearances shown below, drill 2
off 14mm x 100mm holes.
Fit the 2 bolts supplied and hang the wall
bracket.
Fit washers and nuts
Hang the boiler
FROST PROTECTION
the boiler is NOT fitted with frost protection. If the boiler is being installed in a position where freezing
could take place, then a suitable external frost thermostat should be fitted.
CONNECTING TO THE SYSTEM
the boiler is designed to operate on a sealed system (ie. no open vent or feed and expansion cistern)
Hot water expansion within the system is taken up by the internal 10 litre expansion vessel. This is
suitable for systems up to 160 litres capacity. If the system capacity is more than this then an additional
expansion vessel may be required.This can be fitted external to the boiler at a convenient place on the
pipework.
Please note that the circulation pump is fitted to the flow connection.
INSTALL ATIO N RO OM
The appliance must be positioned in such a way as to be easily accessible at all times. In addition, the
following minimum distances around the appliance must be complied with.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV ETech W 36 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV ETech W 36 in the language / languages: English as an attachment in your email.

The manual is 5,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ACV ETech W 36

ACV ETech W 36 User Manual - German - 30 pages

ACV ETech W 36 User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info