620415
13
Zoom out
Zoom in
Previous page
1/30
Next page
EN • 13
ENFRRU PL DE IT ES NL
Delta Pro S / Delta Pro Pack : 664Y4900 • E
TYPE OF FLUE CONNECTION
B23 : Connection to a flue with the combustion air taken directly in the
boiler room.
B23P : Connection to an exhaust system of the combustion products
designed to operate with positive pressure.
C13 : Connection by pipes with horizontal terminals that simultaneously
take in combustion air for the burner and discharge combustion
products outside through openings that are either concentric or
close enough together to be subjected to similar wind conditions.
C33 : Connection by pipes with vertical terminals that simultaneously take
in fresh air for the burner and discharge the combustion products
outside through openings that are either concentric or close enough
together to be subjected to similar wind conditions.
C43 : Connection by two ducts to a collective duct system serving more
than one appliance; this system of collective ducts features two ducts
connected to a terminal unit that simultaneously takes in fresh air for
the burner and discharges the combustion products outside through
openings that are either concentric or close enough together to be
subjected to similar wind conditions.
C53 : Connection to separate ducts for the supply of combustion air and
for venting the combustion products; these ducts may end in zones
with different pressure levels.
C63 : Type C boiler which is intended for connection to a room sealed flue
system which is approved and sold separately.
(Prohibited in Belgium).
Due to the high efficiency of our boilers, the flue gases are
released at low temperature. As a result, there is a risk of
condensation of the flue gases, which could damage some
chimney constructions; to avoid this risk, it is strongly
recommended to line the chimney. To prevent condensates
to flow back into the boiler, we strongly advise to install a
condensates collector. Please contact your installer for more
information.
INSTALLATION
For concentric connection, the total length of the flue must be no more than 6 metres and no less than 1metre (including the terminal).
For double pipe connection (only with gas) :
Gas = 10 metres + 4 pipe bends
Connection type
Models Burners B23 B23P C13 C33 C43 C53 C63
Delta Pro S 25 &
Delta Pro Pack 25
BMV1 / BMR-31 / BMe1
BMV1-FV
BG 2000-S 25
BG 2000-SV 25
Delta Pro S 45 &
Delta Pro Pack 45
BMV2
BMV2-FV
BG 2000-S 45
BG 2000-SV 45
Delta Pro S 55
BMV2
BG 2000-S 55
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV Delta Pro S45 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV Delta Pro S45 in the language / languages: English as an attachment in your email.

The manual is 5,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ACV Delta Pro S45

ACV Delta Pro S45 User Manual - German - 30 pages

ACV Delta Pro S45 User Manual - Dutch - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info