12
BNE : 664Y6000 •D
TECHNICAL CHARACTERISTICS
COMBUSTION CHARACTERISTICS
Main Characteristics BNE 1 BNE 2
Fuel type Oil Oil
Max. input (PCI) kW 28 41
Output at 100% (80/60°C) kW 25 36
Output power min (80/60°C) kW 20 27
Max operating temperature °C 90 90
HYDRAULIC CHARACTERISTICS
Main hydraulic characteristics BNE 1 BNE 2
Water content of the boiler L 184 186
Primary circuit capacity L 64 66
Heating inlet/outlet connection (F) Ø 1" 1"
DHW inlet/outlet connection (M) Ø 3/4" 3/4"
Max. service pressure of DHW circuit bar 7 7
Max. service pressure of heating circuit bar 3 3
Primary circuit water pressure drop (∆T = 20 K) mbar 20 25
DHW PERFORMANCE
Operating conditions at 80°C BNE 1 BNE 2
Peak ow at 40 °C [T = 30 K] L/10' 311 311
Peak ow at 40 °C [T = 30 K] L/60' 908 1060
Constant ow at 40 °C [T = 30 K] L/h 716 899
MAXIMUM OPERATING CONDITIONS
Maximum Service Pressure [DHW tank full of water]
- Primary circuit : .................................................................................................................. 3 bar
- DHW circuit : .................................................................................................................... 8,6 bar
- Recommended safety valve (central heating) : .................................................... 3 bar
- Recommended safety valve (DHW) : ........................................................................ 7 bar
Mains supply pressure
- Max 6 bar, without a pressure reducing valve being required (to avoid discharge of the safety
pressure valve)
Maximum Operating Conditions
- Maximum temperature (central heating) : ............................................................... 90°C
- Maximum temperature (DHW) : ........................................................ from 60°C to 80°C
Water Quality
See “Recommendations for the Prevention of Corrosion and Scaling”.
Oil quality
Low sulfur oil (50 ppm)
Standard oil (2000 ppm)
Bio-oil 0 at 7% methyl esters of fatty acids
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACV BNE 1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACV BNE 1 in the language / languages: English as an attachment in your email.

The manual is 2,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ACV BNE 1

ACV BNE 1 User Manual - German - 36 pages

ACV BNE 1 User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info