B. Main Menu
1. Changes can be made to the factory setting parameter. This is done in the Main Menu. Press
ENTER button to go into the Main Menu.
2. The Main Menu consists of Operation Menu, Settings Menu, Timer Menu, Alarm Menu and
Display Menu.
How to use the Main Menu?
Step 1
Press ENTER to view the sub-Menu under Main Menu.
Step 2
Go to the sub-Menu you want by pressing the 5 or button. Press ENTER to select the sub-Menu.
Step 3
Go to the parameter you want to change or view by pressing the 5 or button. Press ENTER to
select this parameter.
Step 4
Change the parameter by pressing the 5 or button. Once completed press ENTER.
Press ESC to go back to previous screen until you see the initial display screen.
Note: The Set Parameter in the setting menu requires password for any changes to or to view its
parameter.
CAUTION:
All the password entering must be done by local dealer / serviceman. User is not allowed to
change the value of the set parameter as this may cause damage to unit or deter its operation.
Operation Menu
This menu enables us to set the units status (on or off), set the unit operation mode,
set the water in temperature and manually defrost the unit (applicable for heating mode only).
Setting Menu
This menu enables us to set the panel ID (factory setting is [00]), set parameter for unit operation
(requires password entering), change password and set panel option.
The panel option enables us to set the LCD backlight and contrast, set the alarm buzzer, enable and
disable the screen saver and set a screen saver timeout and set the temperature display in °C or °F.
Timer Menu
This menu enables us to set the clock, set the date, set a 7 days schedule to start and stop the unit
and enable or disable the set schedule.
Alarm Menu
This menu enables us to view the alarm history and also clear the record. The panel can keep up
to 20 fault / alarm records.
Display Menu
This menu enables us to view the defrost sensor(s) temperature, discharge sensor(s) temperature
and compressor(s) run time.
OM-WCCH_(ENG) 4/1/04, 5:18 PM2
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Acson WCCH-0703 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Acson WCCH-0703 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info