646707
20
Zoom out
Zoom in
Previous page
1/44
Next page
17
ESPAÑOL
NO TECLA FUNCIÓN
1. ON/OFF Enciende/apaga la unida cancelando todos los ajustes del
temporizador
2. SLEEP Activa/desactiva la función de apagado automático
3. FAN Selección el control de velocidad del ventilador
(Auto/High/Med/Low)
4. MODE Selecciona el control de Modos de funcionamiento
(Cool/Heat/Auto/Dry/Fan)
El modo Auto no está disponible para el Sistema de agua
enfriada
5. SET TEMP UP Aumenta la temperatura seleccionada en °C o °F
6. SET TEMP DOWN Reduce la temperatura seleccionada en °C o °F
7. SWING Activa/desactiva el control de inclinación
8. ON TIMER Activa/desactiva el modo de ajuste de Event 1, 2 y 3 de ON TIMER
9. OFF TIMER Activa/desactiva el modo de ajuste de Event 1, 2 y 3 de OFF
TIMER
10. TIMER ACTIVE Activa/desactiva todos los temporizadores seleccionados
11. CLOCK Activa/desactiva el modo de selección de Reloj de tiempo real
(RTC)
12. DAY a) Selecciona el día para el ajuste de RTC o temporizador
b) Activa/desactiva el bloqueo de la tecla FAN
13. HOUR a) Selecciona la hora para el ajuste de RTC o temporizador
b) Ajusta la función de anulación para 1, 2 ó 4 horas
14. MINUTE a) Selecciona los minutos para el ajuste de RTC o temporizador
b) Activa/desactiva el bloqueo de teclas
1.0 GUÍA DE OPERACIÓN
El controlador con cable Netware 3 tiene 14 teclas.
Nota: Función de anulación
Pulse la tecla HOUR una vez y se activará la función de anulación durante 1 hora. Se mostrará un
indicador “H1” en el ángulo superior izquierdo del LCD. Pulse la misma tecla de nuevo y la selección
aumentará a 2 horas. Se mostrará un indicador “H2”. Pulse una tercera vez y la selección aumentará
a 4 horas. Se mostrará un indicador “H4”. Si vuelve a pulsar se desactivará la función de anulación.
Cuando se activa la función de anulación, se omiten todos los temporizadores y la unidad se pone
en marcha en periodos fijos de 1 hora, 2 horas o 4 horas, dependiendo de la selección, apagándose
posteriormente.
5 OM-NET3-0808_ES 9/5/08, 11:43 AM17
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Acson NET3-0808 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Acson NET3-0808 in the language / languages: English as an attachment in your email.

The manual is 2,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info