515756
131
Zoom out
Zoom in
Previous page
1/165
Next page
129
11. TROUBLESHOOTING
When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before
proceeding with the following troubleshooting procedures.
The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which
are not listed occur, contact your nearest local dealer. DO NOT attempt to troubleshoot the unit by yourself.
No Fault conditions Possible causes / corrective actions
1 The air conditioner unit will not resume after
power failure.
The auto restart function is not functioning. Please
turn on the unit with the wireless / wired controller.
2 The compressor does not operate 3 minutes
after the air conditioner unit is started.
Protection against frequent starting.
Wait for 3 or 4 minutes for the compressor to start
operating by it self.
3 The airflow is too slow or room cannot be
cooled sufficiently.
The air filter is dirty.
The doors and windows are opened.
The air suction and discharge of both indoor and
outdoor units are clogged or blocked.
The regulated temperature or temperature setting
is not low enough.
4 Discharge airflow has bad odor.
Cigarettes, smoke particles, perfume and others,
which might have adhered onto the coil, may
cause odor.
Contact your nearest dealer.
5 Condensation on the front air grille of the indoor
unit.
This is caused by air humidity after an extended
period of operation.
The set temperature is too low. Increase the
temperature setting and operate the unit at high
fan speed.
6 Water flowing out from the air conditioner.
Switch off the unit and contact your nearest
dealer. This might be due to tilted installation.
7 Hissing airflow sound from the air conditioner
unit during operation.
Liquid refrigerant flowing into the evaporator coil.
8 The wireless controller display is dim.
The batteries are discharged.
The batteries are not correctly inserted.
The assembly is not good.
9 Compressor operates continuously.
Dirty air filter. Clean the air filter.
Temperature setting too low (cooling). Use higher
temperature setting.
Temperature setting too high (heating), Use lower
temperature setting.
10 No cool air comes out during cooling cycle, or
no hot air comes out during heating cycle.
Temperature setting too high (cooling). Use lower
temperature setting.
Temperature setting too low (heating). Use higher
temperature setting.
11 On heating cycle, warm air does not come out.
Unit is in defrost mode. Heating operation will
resume after defrost cycle ends.
131


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Acson A5WM 09G-GR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Acson A5WM 09G-GR in the language / languages: English as an attachment in your email.

The manual is 17,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info