1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
General Data - Heatpump (R410A)
M5WM 010GR M5WM 015GR
M5LC 010CR M5LC 015CR
Btu/h
9500 12000
W
2780 3520
Btu/h 9500 12000
W 2780 3520
W 867 1230
W 747 1080
A 3.9 5.4
A 3.4 4.9
V/Ph/Hz
W/W
3.21 2.86
W/W
3.72 3.26
HIGH l/s / cfm 142 / 300 163 / 345
MEDIUM l/s / cfm
118 / 250 135 / 285
LOW l/s / cfm
94 / 200 104 / 220
dBA
39 / 34 / 28 42 / 36 / 29
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg/lb
mm/in
l/s / cfm 396 / 840 453 / 960
dBA 46 49
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg/lb
LIQUID mm/in
GAS mm/in 9.52 / 3/8 12.70 / 1/2
kg/lb 0.73/1.61 0.825/ 1.82
6.35 / 1/4
810/31.9
330/13.0
32/70.55
FLARE VALVE
540/21.3
700/27.6
250/9.8
620/24.4
957 / 37.7
270 / 10.6
12/26.46
16 / 0.63
260 / 10.2
899 / 35.4
198 / 7.8
337 / 13.3
COP
REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP. TUBE
REFRIGERANT TYPE
220-240/1/50
R410A
DOUBLE LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL
AIR FLOW
INDOOR UNIT
CONTROL
AIR DISCHARGE
OPERATION
UNIT DIMENSION
PACKING DIMENSION
AIR FLOW
SOUND PRESSURE LEVEL (H/M/L)
TYPE
SIZE
REFRIGERANT CHARGE
UNIT DIMENSION
EER
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
PACKING DIMENSION
OUTDOOR UNIT
UNIT WEIGHT
CONDENSATE DRAIN SIZE
SOUND PRESSURE LEVEL
UNIT WEIGHT
PIPE CONNECTION
MODEL
OUTDOOR UNIT
INDOOR UNIT
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
A5WM 10GR A5WM 15GR
A5LC 10CR A5LC 15CR
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Acson A5WM 09G-GR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Acson A5WM 09G-GR in the language / languages: English as an attachment in your email.

The manual is 17,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info