Programming Keys
Oven is shipped from the factory for single key programming. To change
the oven default to allow double key programming, see User Option
section. To change the amount of time or the power level for a preset key:
1. Open oven door.
READY displays.
If door is closed or STOP key is pressed before programming is complete,
changes are discarded and microwave exits programming mode.
2. Press and hold key 1 for approximately 5 seconds.
This begins programming mode.
Microwave will beep and PROGRAM displays. Oven is in
programming mode.
3. Press key to be reprogrammed.
Press two keys if reprogramming a double pad program.
Power level and cooking time display.
If power level does not display, microwave is set to full power.
4. Enter cooking time by using the number keys.
5. Press a power level key to change power level if desired.
6. Press START key to save new programming changes to the key.
PROGRAM displays.
If START is not pressed, changes will not be saved.
7. Press STOP/RESET key or close oven door to exit
programming mode.
Programming the Oven Control (Electronic Control)
Programming Multiple Stages
Stage cooking allows consecutive cooking cycles without interruption.
Up to four dierent cooking cycles can be programmed into a memory key.
To use stage cooking:
1. Follow steps 1 through 5 above.
6. Press TIME ENTRY key.
• Display briey shows the key number that is being programmed and
the stage number to the upper right.
Display changes to cook time and power level for the next stage.
7. Enter cook time and power level as in steps 4 and 5.
• To enter another cooking stage for that key, press
TIME ENTRY key again.
• Up to four dierent stages can be programmed.
8. Press START key to save new programming changes to the key.
9. Press STOP/RESET key or close oven door to exit programming
mode.

PROGRAM.
When set to single key or
double key programming,
the display will show PROGRAM
when programming keys for single
or double digit cooking sequenses.
To change the oven’s default to
allow either single key or double key
programming, see the User Option
section.
QTY X2
Programming
This feature allows a preset
percentage of original cook
time, called a cooking factor, to
be added to a cook sequence.
To change the cooking factor:
1. Open oven door.
2. Press and hold key 1 for
approximately 5 seconds.
3. Press key to be reprogrammed.
4. Press the QTY X2 key.
5. Press a numbered key to
change the cooking factor.
• Cooking factor can be set
from 10% to 100%.
• Default is 80%.
• Key 5 would change the
cooking factor to 50%.
• Key 3 would change the
cooking factor to 30%.
6. Press START key to save
changes.
Canceling Mistakes
If oven is not cooking, press
STOP/RESET key to clear
display. If oven is cooking,
press STOP/RESET key once to stop
oven, then again to clear display. If
oven door is open and time shows in
display, close oven door and press
STOP/RESET key to clear display.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACP RCS511DSE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACP RCS511DSE in the language / languages: English as an attachment in your email.

The manual is 2,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ACP RCS511DSE

ACP RCS511DSE User Manual - German - 16 pages

ACP RCS511DSE User Manual - Dutch - 12 pages

ACP RCS511DSE User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info