660229
13
Zoom out
Zoom in
Previous page
1/17
Next page
13
Digital Dial Operation
Digital Dial option is available on some models only.

Oven Wall Clearances
A—For North American (UL/CSA) models, allow
at least 2” (5.1 cm) of clearance around top
of oven. For International (50 Hz) models,
allow at least 12” (30 cm) of clearance
oven cools electrical components. With
properly and life of electrical parts is
reduced.
B—Allow at least 2” (5.1 cm) between air
discharge on back of oven and back wall.
C—Allow at least 2” (5.1 cm) of clearance around
sides of oven.
No metal pans
DO NOT power spray
So...how do I use it? (Electronic / Mechanical Dial)
Heating
1. Open oven door, place food in oven, and close oven door.
2. Select desired power level or use default 100%.
2. Turn time entry knob clockwise to desired time.
Cooking time can be set up to 10 minutes.
Oven begins operation and time counts down.
3. When cooking time has elapsed, microwave energy stops and oven signal sounds.
Interrupting Operation
Open oven door to interrupt operation or turn time entry knob counterclockwise to “0”.
To resume microwave oven operation, close door, select power level pad, and turn knob.
Changing Time and Canceling Mistakes
Heating time and power level can be changed at any time while the oven is operating.
Press power level pad or turn knob to desired new setting. To set cooking time to zero,
turn knob counterclockwise to “0” or cycle door open and closed.
C
A
B
0
1
15
15
30
30
45
45
2:00
1:00 - 2:00
:30
:15
:45
1:30 - 2:30
2
3
4
5
6
7
8
9
10
Menu Guide
20% 50% 70% 100%
20%
70% 100%
50%
Changing Timer Option
Timer resetting to zero can be set at any time to pause current cook time and power level when door is
opened. To change this option follow the step below.
With door open press and hold the 100% pad
100%
for 5 seconds until beep is heard. Close the
door this changes timer setting to pause current cook time and power level when door is opened.
Timer pausing current cook time and power level can be set at any time to reset to zero and 100%
power level when door is opened. To change this option follow the step below.
With door open press and hold the 20% pad
20%
for 5 seconds until beep is heard. Close
the door this changes timer setting to reset timer to zero and power level to 100% when door is
opened.
The switching operation of this microwave oven can cause voltag der unfavorable voltage
supply conditions can have adverse effects. This device is intended for the connection to a power supply system with a maximum permissible system
impedance Zmax of 0.2 Ohms at the interface point of the user’s supply. The user has to ensure that this device is connected only to a power
at
the interface point.
Oven Wall Clearances
A—Allow at least 2” (5.1 cm) of clearance around top of
oven. Proper air ow around oven cools electrical
components. With restricted air ow, oven may not
operate properly and life of electrical parts is reduced.
B—There is not an installation clearance requirement for the
back of the oven.
C—Allow at least 1” (2.54 cm) of clearance around sides of
oven.
D—Install combination oven so oven bottom is at least 3
feet (91.5 cm) above oor.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ACP RCS10TS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ACP RCS10TS in the language / languages: English as an attachment in your email.

The manual is 2,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ACP RCS10TS

ACP RCS10TS User Manual - German - 16 pages

ACP RCS10TS User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info