RTSP
Port range: The standard port range for RTP unicast transmission is 5000–7999. As an alternative,
the port range 1024–65534 can be used.
RTSP port: The standard port for RTSP transmission is 554. As an alternative, this port can be
assigned a value in the range of 1024–65534. If several IP cameras are located in the
same subnetwork, then each camera should have its own unique RTSP port.
Profile name: The access names for the various RTSP streams are configured here. Select the
profile to be edited (H.264, MPEG-4, MJPEG, or 3GPP).
Profile: Configuration of the access name for the selected profile.
Authentication: Access to the relevant RTSP stream can be protected with a user name and password.
Examples:
Authentication from: rtsp://192.168.0.100:554/video.h264
Authentication to: rtsp://admin:12345@192.168.0.100:554/video.h264
Multicast:
Multicast designates message transmission from one point to a group (also referred to as a multi-point
connection). The advantage of multicast is that messages can be transmitted simultaneously to several
recipients or a closed user group without the bandwidth of the sender increasing according to the number of
recipients. When using multicast, the sender only requires the same bandwidth as a single recipient. The
packets are multiplied on each network distributor (switch, router).
In IP networks, multicast enables efficient sending of data to many recipients at the same time. This is
accomplished with a special multicast address. In IPv4, the address range 224.0.0.0 to 239.255.255.255 is
reserved for this purpose.
Status: Activated/deactivated
Access name: The access name for RTSP access is configured here.
Multicast address: Entry of the multicast server address
Video port: Automatic or manual assignment of the multicast video port.
Audio port: Automatic or manual assignment of the multicast audio port.
TTL (Time-To-Live): Length of time the packet is kept before being discarded.
UPnP
The UPnP (Universal Plug and Play) function makes it easy to control network devices in an IP network. This
allows the network camera to be seen in the Windows network environment (e.g. as a network device).
UPnP: Enable or disable the UPnP function.
Enable UPnP Port forwarding: This enables Universal Plug and Play port forwarding for network
services. If your router supports UPnP, then port forwarding for video
streams is activated automatically on the router for the network camera
using this option.
HTTP port: The standard port for HTTP transmission is 80. As an alternative, this
port can be assigned a value in the range of 1024–65535. If several IP
cameras are located in the same subnetwork, then each camera
should have its own unique HTTP port.
SSL port: The standard port for SSL transmission is 443. As an alternative, this
port can be assigned a value in the range of 1024–65535. If several IP
cameras are located in the same subnetwork, then each camera
should have its own unique SSL port.
RTSP port: The standard port for RTSP transmission is 554. As an alternative, this
port can be assigned a value in the range of 1024–65535. If several IP
cameras are located in the same subnetwork, then each camera
should have its own unique RTSP port.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus tvip1551 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus tvip1551 in the language / languages: English as an attachment in your email.

The manual is 1,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Abus tvip1551

Abus tvip1551 User Manual - German - 60 pages

Abus tvip1551 User Manual - Dutch - 58 pages

Abus tvip1551 User Manual - Danish - 59 pages

Abus tvip1551 User Manual - French - 60 pages

Abus tvip1551 User Manual - Polish - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info