Note
1)
Observe the polarity of the output, normal or inverted (Secvest programming) in con-
junction with the type setting low or high (wAppLoxx Control programming) combined
with the plus and minus wiring.
Note
Observe the wAppLoxx Control power consumption.
If 500 mA at the “0 V / 12 V AUX” output is insufficient, supply the wAppLoxx Control
directly from the PSU. You must then also observe the maximum current output of the
PSU.
Observe the permissible voltage range of the wAppLoxx Control.
12 V +/-10% = 10.8 V - 13.2 V
You may need to use a separate power supply unit for the wAppLoxx Control.
Note
Note the contact capacity (current, voltage) of the relay.
Note
You can configure the outputs (type, name, partitions, polarity, options) in installer
mode -> outputs -> HyMo outputs
Note
4.
Observe the wiring of the relay NO/COM or NC/COM (wAppLoxx Control) in conjunc-
tion with the type switch on or switch off (wAppLoxx Control programming) combined
with the property of the wired zone, inverted or not inverted (Secvest programming).
Note
3)
Note the zone wiring
The wired zone type can be configured separately for each hybrid module.
The wired zone type applies to all 10 or 5 zones/inputs of the respective hybrid mod-
ule.
You can configure this setting in installer mode -> components -> hybrid module.
Note
You can configure the zone programming (type, name, partitions, properties) in in-
staller mode -> components -> HyMo zones
Note
4)
The wire loop in Z8 is used for tamper monitoring of the connection cable between
the Secvest alarm panel and wAppLoxx Control.
73


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus FUMO50110 - Secvest at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus FUMO50110 - Secvest in the language / languages: English, German, Dutch, Danish, French, Italian as an attachment in your email.

The manual is 2,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info