Connection example of an accessory module to a connected
alarm system, e.g.: Terxon S. Note that the jumpers are all
removed and the outputs are working as relays (NC).
Inverting relay outputs
You can reprogram the relay outputs individually to work as NC
instead of NO. Reprogramming relay outputs affects all function
modes. To reprogram the relay channels, proceed as follows:
In the main programming menu, select item 5 (LED 5 lights
up).
Confirm by pressing SET.
LED 1 lights up or flashes to show output 1.
You are now in the submenu of item 5. Select the output where
the polarity is to be changed. To select the output, press
SELECT.
Confirm the selection of the output by pressing SET.
The LED of the selected output flashes or lights up.
To change the polarity of the output, press SELECT.
A constantly lit LED means that this output is programmed as
NO. A flashing LED means that this output is programmed as
NC.
After setting the polarity of the output, confirm the selection by
pressing SET. You now return to the output selection menu.
After setting the outputs, exit the programming mode by pressing
ESC/DEL.
The LED for the power supply lights up/flashes and the fault LED
lights up. The accessory module beeps at short intervals.
Close both tamper contacts of the WAM and wait until it emits
a double tone.
In this example, dip switches 2, 3 and 4 of the accessory module are
set to ON. Battery faults, supervision failure and jamming all activate
output 4 of the WAM.
First-detector recognition:
Output 1 of the alarm centre is connected to input 1 of the
accessory module. If the alarm centre is activated, this output
switches against ground (0 V) and remains so until the system is
deactivated.
After the alarm centre is deactivated, the LED of the detector
channel that was triggered first flashes on the accessory module.
LEDs on detector channels that have also triggered light constantly
on the accessory module.
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus fumo50020 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus fumo50020 in the language / languages: English, German, Dutch, Danish, French, Italian as an attachment in your email.

The manual is 2,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info