Technical data
8 EN
a fault report is sent to the alarm control panel and the user is
informed. The external power supply is not monitored in this
mode.
During operation with an external power supply (DIP
switch 3 deactivated), a fault report is sent to the alarm control
panel as soon as this is interrupted. The wireless control panel
is then automatically powered by the batteries. The
corresponding notification on the alarm control panel informs
the user about this. How a battery test can be carried out is
described above.
Type of power
supply
Type B (50131-1 §9 und 50131-6 §4.1)
external power supply via power supply unit and batteries
inserted as a backup power supply
Type C (50131-1 §9 und 50131-6 §4.1)
battery operation only, without external power supply via
power supply unit
Power supply compliant with
EN50131-1:2006+A1:2009 9.2 and EN50131-6 if installed
correctly together with Secvest Wireless Alarm System
FUAA50xxx
Environmental class
II (EN50131-1 §7, EN50131-3 §7)
Encryption
16.777.214 (2
24
2) variants
Certifications
EN50131-3
Access code
4-digit or 6-digit
Conformity
The device is compliant with EN 50131-1, EN50131-3:2009,
EN50131-5-3 and EN50131-6 security level 2 if installed
correctly together with Secvest Wireless Alarm System
FUAA50xxx (verified by ANPI).
EU Directives
RED: 2014/53/EU, EMC: 2014/30/EU, RoHS: 2011/65/EU
WEEE: 2012/19/EU, ErP: 2009/125/EC, Low Voltage:
2014/35/EU, General Safety: 2001/95/EC
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus FUBE50001 - Secvest at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus FUBE50001 - Secvest in the language / languages: German as an attachment in your email.

The manual is 1,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info