NO1, C1, NC1 – Relaisausgang 1: potentialfreier
Relaiskontakt,24VACrms/500mA
NO2, C2, NC2 – Relaisausgang 2: potentialfreier
Relaiskontakt,24VACrms/500mA
OP3/4 – Transistorausgänge:füreine
verdrahtete
Sirene, Blitz und Tonsignalgeber
TR – Tamper Return: Sabotageeingang
einer verdrahteten Sirene
TRB – Trouble: Störungsmeldungseingang
einer verdrahteten Sirene
Z301, Z302: Drahtzonen 301 und 302
Z303,304: Drahtzonen 303 und 304
0V, 12V Aux: Spannungsausgang 13,8 V
DC IN 13,8V +: Anschluss Spannungsversorgung 13,8 V
NO1, C1, NC1 – relay output 1: Free of potential
relaycontact,24VACrms/500mA
NO2, C2, NC2 – relay output 2: Free of potential
relaycontact,24VACrms/500mA
OP3/4 – transistor output: For a wired sounder,
ashingandaudioalarmsignallingdevice
TR – tamper return: Tamper input from a
wired sounder
TRB – trouble: Malfunction indication input
from a wired sounder
Z301, Z302: wired zones 301 and 302
Z303,304: wired zones 303 and 304
0V, 12V aux:voltageoutput13.8V
DC IN 13,8V +:connectionforvoltagesupply13.8V
NO1, C1, NC1 – sortie relais 1 :
Relais libre de
potentiel,24VCArms/500mA
NO2, C2, NC2 – sortie relais 2 :
Relais libre de
potentiel,24VCArms/500mA
OP3/4 – sortie transistor : Pour une sirène câblée,
ashettransmetteurdesignauxsonores
TR – Tamper Return : Entrée sabotage d’une
sirène câblée
TRB – Trouble : Entrée de signal de
dérangement d’une sirène câblée
Z301, Z302 :Zoneslaires301et302
Z303, 304 : Zoneslaires303et304
0V, 12V Aux : Sortie de tension 13,8 V
DC IN 13,8V + : Raccordement de l’alimentation
en tension 13,8 V
NO1, C1, NC1 – relaisuitgang 1: Potentiaalvrij
relaiscontact,24VACrms/500mA
NO2, C2, NC2 – relaisuitgang 2: Potentiaalvrij
relaiscontact,24VACrms/500mA
OP3/4 – transistoruitgangen: Voor de bedrading
vansirene,itslichtenakoestischalarm
TR – Tamper Return: Sabotage-ingang voor
sirenebedrading
TRB – Trouble: Storingsmeldingsingang voor
sirenebedrading
Z301, Z302: Draadzones 301 en 302
Z303,304: Draadzones 303 en 304
0V, 12V Aux: Spanningsuitgang 13,8 V
DC IN 13,8V +: Aansluiting voedingsspanning 13,8 V
NO1, C1, NC1 – Relæudgang 1: Potentialefri
relækontakt,24VACrms/500mA
NO2, C2, NC2 – Relæudgang 2:
Potentialefri
relækontakt,24VACrms/500mA
OP3/4 – Transistorudgange: Til kabelforbundet
sirene, blitz og tonesignalgiver
TR – Tamper Return:
Sabotageindgang til
kabelforbundet sirene
TRB – Trouble:
Fejlmeldeindgang til
kabelforbundet sirene
Z301, Z302: Kabelzone 301 og 302
Z303,304: Kabelzone 303 og 304
0V, 12V Aux:Spændingsudgang13,8V
DC IN 13,8V +:Tilslutningspændings-
forsyning 13,8 V
NO1, C1, NC1 – Uscita relè 1: Contatto relè a
potenzialezero,24VCArms/500mA
NO2, C2, NC2 – Uscita relè 2: Contatto relè a
potenzialezero,24VCArms/500mA
OP3/4 – Uscite transistor: Per sirena cablata,
ashesegnalatoreacustico
TRB – Trouble: Ingresso antisabotaggio di
una sirena cablata
TRB – Trouble: Ingresso messaggio di guasto
di una sirena cablata
Z301, Z302: Zone cablate 301 e 302
Z303,304: Zone cablate 303 e 304
0 V, 12 V Aux: Tensione di uscita 13,8 V
CC IN 13,8 V +: Collegamento per alimentazione
di tensione 13,8 V
Übersicht Klemmleiste Anschlüsse
Overview of terminal block connections • Vue d‘ensemble connecteurs bornier • Overzicht aansluitingen op klemlijst • Oversigt
klemmerække tilslutninger • Panoramica morsettiera collegamenti
NO1, C1, NC1
Z301, Z302
Z303,304
0V, 12V Aux
DC IN
NO2, C2, NC2
OP3/4
TR
TRB
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus FUAA50010 - Secvest at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus FUAA50010 - Secvest in the language / languages: English, German, Dutch, Danish, French, Italian as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Abus FUAA50010 - Secvest

Abus FUAA50010 - Secvest Installation Guide - German - 399 pages

Abus FUAA50010 - Secvest User Manual - German - 84 pages

Abus FUAA50010 - Secvest Installation Guide - Dutch - 261 pages

Abus FUAA50010 - Secvest User Manual - Dutch - 82 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info