8-42
22
22
44
ZZZZ
+
1010
I+Instant
(Interior+Instant)
Armed
The I+Instant zone type is similar to zone type Instant. However, this zone type is not
monitored for an internally activated system.
22
22
44
ZZZZ
+
1111
UO Trigger
Armed
The UO Trigger zone type controls a switch output whether the system is active or inactive.
For example: for temperature sensors that control a ventilator.
22
22
44
ZZZZ
+
1212
Day Zone
Armed
A zone with the Day Zone zone type immediately triggers an alarm in an internally or
externally activated system. If the system is inactive, a fault is displayed on the alarm
system display. The fault message can now control a switch output or be viewed by the
user in the user menu under
Troubles. This zone type is mostly used to protect emergency
exits.
22
22
44
ZZZZ
+
1313
24 Hours
Default for zone 3 All
A zone with the 24 Hours zone type triggers an alarm immediately, irrespective of the
state of the alarm system. This zone type is mostly used for passive glass breakage
sensors.
22
22
44
ZZZZ
+
1414
Fire
Default for zone 3 All
A zone with the Fire zone type triggers a fire alarm immediately, irrespective of the state of
the alarm system. This zone type is used for smoke detectors.
NOTE:
Zone 33 cannot be programmed as a fire zone.
22
22
44
ZZZZ
+
1515
Panic
All
A zone with the Panic zone type triggers a panic alarm immediately, irrespective of
the state of the alarm system. This zone type is not intended for panic messages
triggered by remote control. See the
key-fob menu.
22
22
44
ZZZZ
+
1616
Special
All
A zone with the Special zone type triggers a medical emergency alarm (not a panic
alarm) immediately, irrespective of the state of the alarm system.
22
22
44
ZZZZ
+
1717
Pulse Keyswitch
A zone with the Pulse Keyswitch zone type can be used to activate/deactivate an
area. The state change must be in the form: closed – open (pulse) – closed.
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abus FU9000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abus FU9000 in the language / languages: English as an attachment in your email.

The manual is 2,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Abus FU9000

Abus FU9000 User Manual - English - 56 pages

Abus FU9000 Installation Guide - German - 96 pages

Abus FU9000 User Manual - German - 55 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info