7. Default settings in your Control Medi
On delivery your Control Medi Standard will be set with certain default settings as follows:
Acceptance delay is set to value OFF
Feedback sound level is set to value 1 (0 5)
Feedback vibration level is set to value 1 (0 5)
Only level 1 is open, other levels are closed
GewaLink channels 16-39 are on level 1-4
A random code on the
!
button
7.1 Resetting to Default settings
It is possible to reset one button, reset all buttons on one level, or reset the entire Control
Medi to default settings. See Table 1 Default setting Gewa Link channels, which shows you
which channels are set after a reset. Other settings will also return to default settings, see
above.
Do the following to restore:
1. First press
---
and then simultaneously press
3
for 2 seconds. When you release the
buttons the “Setting” alert sounds and the indication lamp on button 3 flashes.
2a. Reset one button:
Press
2
.
Choose the level with
---
.
Choose the button
X
to be restored.
or:
2b. Reset all buttons on one level:
Press
3
.
Choose the level with
---
.
Press
1
.
or:
2c. Reset to factory settings (all buttons on all levels):
Press
1
.
Press
1
,
2
,
3
in sequence
.
3. If the action is successful, the “Success” alert sounds. If something goes wrong or takes
too long, the “Error” alert sounds.
Resetting to default settings
To reset one button:
Press
---
+
3
2 sec
,
2
, choose level with
---
, then choose button
X
.
To reset one level:
Press
---
+
3
2 sec
,
3
, then choose level with
---
,
1
.
To reset to factory settings:
Press
---
+
3
2 sec
,
1
,
1
,
2
,
3
.
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abilia 429220 Gewa Control Medi Standard at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abilia 429220 Gewa Control Medi Standard in the language / languages: English, Swedish as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Abilia 429220 Gewa Control Medi Standard

Abilia 429220 Gewa Control Medi Standard User Manual - German, French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info