16. Teknisk information
16.1 Mottagare IR-REC8 BED
Drivspänning:
12-24 V DC
Effektförbrukning i vila:
0,15 W
Effektförbrukning, max:
1,6 W
Max belastning per relä:
200 mA/30 V AC, 350 mA/60 V DC
Programmeringskanaler:
GewaLink-kanalerna 0-61,
63-127 och 4096-kod.
Levereras med GewaLink-kanaler 64-71.
Kapslingsklass:
IP 54
Temperaturområde:
0° till +40°C
Användningsområde:
Inomhus. Upp till 2000 m över havet.
Förvaring och transport:
-20° till +60°C, relativ fuktighet 80% icke
kondenserande.
16.2 Strömadapter MEAN WELL GEM18I AC-DC Adaptor
Ingående:
Spänningsområde:
80-264 V AC
Frekvensområde:
47 63 Hz
Utgående:
DC-spänning:
12 V
Märkström:
1,5 A (1,35 A vid 100 V AC)
16.3 Reläkonfiguration 10-polig skruvplint
1
Utgång relä 1
2
Utgång relä 2
3
Utgång relä 3
4
Utgång relä 4
5
Utgång relä 5
6
Utgång relä 6
7
Utgång relä 7
8
Utgång relä 8
9
Gemensam ingång
10
Ingen funktion
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abilia 419891 Gewa Andromeda IR-REC8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abilia 419891 Gewa Andromeda IR-REC8 in the language / languages: English, Swedish, Norwegian as an attachment in your email.

The manual is 0,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info