677205
13
Zoom out
Zoom in
Previous page
1/44
Next page
13
Connections
All terminals are detachable, so that they can be removed before connecting wires.
The figure shows how wires are to be connected.
External detector
The detector is the actual eye that receives the IR-signal. There is an internal detector on the
circuit board of the receiver. The colors of the wires are to be connected as shown in the
figure when connecting an external detector. Make sure that the wires are correctly
connected when connecting a detector.
There are two terminals for connecting external detectors. It is possible to connect more than
two external detectors by connecting them in parallel on the existing terminals. A maximum
of 5 pcs can be connected.
Note! The range will be reduced if the detector eye is covered or hidden in some way, for
example by curtains or furniture.
Connecting control switch
There are two terminals for connection of control switches to Gewa Andromeda. A control
switch is connected to the terminal for external detectors. For example, an elbow switch can
be connected.
Note! When the relay is activated by a control switch, the relay is held about 0.5 seconds
after releasing the control switch.
Relay Connection
The receiver has two alternating relay contacts. Inductive loads, such as motors and relays,
should be connected through a disturbance filter. The maximum relay loading is specified in
the Technical specifications.
Power supply
The receiver is powered with 12-24V AC/DC (-10% - +20%).
Power supply input
12-24V AC/DC
Detector 1
(Internal)
4 5 6
RE 2
Relay output
Programming
buttons:
P
4
3
2
1
~
1 2
White
White
Brown
Brown
1
3
2
4
Terminal for
external
detectors/
control
switch
Indicator-
lamp
1 2 3
RE 1
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Abilia 419812 Gewa Andromeda REC2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Abilia 419812 Gewa Andromeda REC2 in the language / languages: English, German, French, Swedish, Norwegian as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info